To gain access turn the green knob to FREE. You can then pull the front plate down and lift the printer head up.  +, The instructions for both the Inner & Outer wound labels are on the inside of the open lid. <br/>  +, There will be no ribbon and as the settings will be for Peel Off a length of blank backing needs to be fed onto the Rewind spool  +,
Sensitivity also needs settings 5 full turns after turning anticlockwise until it goes Sensitivity then turn clockwise until on then the 5 turns.  +, Place a clean, white profile or sheet of paper in the clamps and adjust the Y axis position so the laser dot can be seen below it Focus the laser to make the dot as small as possible on the base of the profile  +
Go to '''Control Panel > Network and Sharing Centre'''. <br/><div class="icon-instructions info-icon"> <div class="icon-instructions-icon"><i class="fa fa-info-circle"></i></div> <div class="icon-instructions-text">Alternatively you can access the Network and Sharing Centre by right clicking the network icon in the bottom right toolbar on the windows desktop.</div> </div><br/>  +, Now go to '''Change Adaptor Settings'''  +, Go to the connected network and '''Right-Click > Properties'''  +,
Sometimes there is no possible way of connecting to a Beckhoff PC due to an IP address conflict. In this case there are two options: # The '''customer''' must find a monitor with DVI port, DVI cable, USB keyboard, USB mouse and complete the next steps. # Connect to the PLC via '''Remote Desktop''' from the front end PC using the PLC name (i.e F050B)  +, When changing a permanent IP address it must be changed to an IP address that has been reserved. The customer is the only person that can assure this. If we cannot gather a permanent IP address put address as high to 250 as possible. Check this IP address is not taken by pinging it. All other information can be gathered through typing '''ipconfig/all''' in the command prompt.  +, #Go to '''Start''' #'''Control Panel''' #'''Network Connection''' #There will be two networks present: one will show EtherCAT; the other '''EtherNET''' or '''Local Area Connection, Right Click''' on this and go to '''Properties.''' #Scroll down the connection options and left click the text of '''Internet Protocol (TCP/IP)''' and click '''Properties''' #Input IP address, subnet mask and default gateway, preferred and alternate DNS server. #Click '''OK''' to submit.   +
Go to '''Control Panel > Network and Sharing Centre'''. <div class="icon-instructions info-icon"> <div class="icon-instructions-icon"><i class="fa fa-info-circle"></i></div> <div class="icon-instructions-text">Alternatively you can access the Network and Sharing Centre by right clicking the network icon in the bottom right toolbar on the windows desktop (see picture).</div> </div><br/>  +, Now go to '''Change Adapter Settings'''  +, Go to the connected network and '''Right-Click > Properties'''  +,
Using any Stuga PC on the same network as the target machines, search for the program '''CameraSetup.exe'''.  +, When the CameraSetup program is loaded it will show all cameras connected on the network. Select one of these and click '''Setup'''. This will prompt for a username and password. Username: '''admin''' Password: '''admin'''  +, Input the '''desired IP Address, Subnet Mask, Default Gateway, Preferred''' and '''Alternate DNS Servers'''.  +
<div class="icon-instructions dont-icon"> <div class="icon-instructions-icon"><i class="fa fa-hand-paper-o"></i></div> <div class="icon-instructions-text">Do not alter anything on the 'Tool' Settings' side.</div> </div><br/>  +, The selected spindle's 'Tool' should now be set to <Empty>. Now press Save.  +, Using the 'Spindle Setup' menu box, select the spindle to be turned off. Using the drop down arrow circled, change the spindle 'Tool' to <Empty>  +,
From here we can see there are no comms, and more importantly the devices name. This name can be cross referenced from the wiring diagrams to find where it is located.  +, For more advanced information, see [[Diagnosing EtherCAT Issues - Advanced]]  +
U
To make the item status of a product inactive it needs to comply with all of the following conditions : Item has 0 in stock Item has 0 in quarantine Item does not exist on any live sales orders Item does not exist on any live purchase orders Item does not exist on any live works orders Item does not exist on a bill of material <br/><div class="icon-instructions caution-icon"> <div class="icon-instructions-icon"><i class="fa fa-exclamation-triangle"></i></div> <div class="icon-instructions-text">Please make a note of changes that are made stock levels allocations P.Os Works orders or BOM lists are amended to make an item inactive as these will have to all be re-entered after the unit of measure has been amended and saved.</div> </div><br/>  +, In the amend stock record window, click on the 'units of measure' tab. Amend Stock unit of measure (the unit in which the item is stocked/brought in as) and manufacturing units of measure (the unit to be converted to on BOM / Works Order lists) as required. If the unit required is not on the list in the dropdown boxes see next step. <div class="icon-instructions info-icon"> <div class="icon-instructions-icon"><i class="fa fa-info-circle"></i></div> <div class="icon-instructions-text">'Stock Unit of Measure' is the unit used in Sage Accounts.</div> </div><br/>  +, If a new unit is needed, go to: Settings > Stock Control > Units Then add in the required measurement to the top line and save.  +,
Located in the dropbox folder D:\Dropbox (Stuga Machinery Ltd)\service\3rd Party Manuals\Servos\Baldor  +, # Select Tools->Download Firmware # Select Nextmove ESB and download the file # Select Yes at the warnings and wait for download to complete   +, # Open File IgSaw 4.62 (get a copy from g:\builds\Latest Software Versions\Saw.mnt # Select Program->Compile, Download and Run   +,
On the desktop of the Beckhoff PC, right click the Twincat Icon in the taskbar and select "About Twincat..." TwinCAT version is displayed. 3.4024.xx is needed <div class="icon-instructions info-icon"> <div class="icon-instructions-icon"><i class="fa fa-info-circle"></i></div> <div class="icon-instructions-text">...The .xx is the build number. Generally, all .xx will be compatible, they release a new build number for bug fixes but will change the main version number when it becomes incompatible</div> </div><br/>  +, The XAR version, not the FULL version Download it via teamviewer to the desktop of the Beckhoff PC you are updating  +, Double click to run the update Click on ok for all defailts and allow all software from Beckhoff  +,
If you have I/O connected but do not see a device with (EtherCAT) then check that the drivers have been installed.  +, The ethernet connection should be connected to the top port - this should display "Connected" The I/O (EtherCAT) port should be the other one. Rename this adaptor "EtherCAT"  +, Open file explorer and navigate to C:\TwinCAT\3.1\System and open TcRteInstall.exe  +,
# Right click on the teamviewer icon in the taskbar (bottom right of screen) # Select Exit Teamviewer   +, # Go to Control Panel->Programs and features # Find Teamviewer Host # Uninstall it, but do not tick the box that says "Remove all settings" <div class="icon-instructions info-icon"> <div class="icon-instructions-icon"><i class="fa fa-info-circle"></i></div> <div class="icon-instructions-text">...Keeping the settings means that the PC will keep the same teamviewer id</div> </div><br/>   +, [https://download.teamviewer.com/download/version_13x/TeamViewer_Host_Setup.exe Download here]  +,
Both the zip files for the install of the Zdownloader and the ZPL version file can be located in G:\Builds\Install Files\Zebra Firmware. there is a manual for using the Zdonloader in with the zip file containing the ZPL version file .  +, Extract the application from the zip file , run and follow the install wizard.  +, When the Firmware file has been selected the file location will appear in the 'Download File' column. Right click again on the printer and select 'Download to Selected' Once complete the firmware version has been downloaded to the Printer, it should then run a calibration and test page off. The Zdownloader can be exited without saving as it only saves the printer detection list.  +,
* Go to Control Panel > Programs and Features > Uninstall a program * Scroll to 'EloMultiTouch' and click uninstall. Touchscreen will still work at this point as the Windows system takes over. However the new one still needs to be installed to allow for calibration.   +, <nowiki>* Go to https://www.elotouch.com/support/downloads#/<br />* On 'Select Product Category' (1) select 'Touch Drivers'<br />* On 'Select Operating System' (2) select whatever operating system the PC you are installing the driver on is running i.e Windows 10.<br />* On 'Current and Legacy' (3) select 'Current'<br />* You will be left with two options 'Multi-Touch Driver' and 'Single-Touch Driver'. Click on 'Multi-Touch Driver' (4). This will begin the download.</nowiki>  +, * Open the downloaded file. This will begin the install. * Click 'OK' * Click 'Unzip' * Click 'OK' * Click 'Yes' * Click 'I Accept the License Agreement' * Wait for setup to finish * Click 'OK'   +,
If the PC is Windows XP, it has to be replaced. All XP machines are over 5 years old now, so well beyond their expected lifespan and should be replaced anyway. <br/>  +, Select all the files in the c:\saw directory, but not the subfolders. Add to a zip file and call it backup  +, From G:\Builds\Latest Software Versions\Saw.Windows <br/>  +,
Offer up the guard over the conveyor walls (the guard sits outside of the walls). The aim is that the smaller radius on the guard is concentric with the top roller.  +, When the guard is in the correct place, mark off 2 holes on both walls (so 4 in total). Remove the guard  +, Drill the holes into the walls, and deburr  +,
Slide the shaft into the gearbox, and secure in position with the circlips  +, Secure the motor/gearbox into position on the mount plate, in the orientation shown, using the M6 bolts and washers  +, Offer up the machined coupling to the shaft  +,
This will keep the plate captive, but will allow for movement  +, Transfer arm can then be installed, using the floating M8 tapped holes on the backing plate. Tighten the M8 bolts securely.  +, Once everything is in position, tighten the M6 bolts. This allows the plate to stay in position, even when the machine is broken down for transportation.  +
Remove all existing parts, including the profile lever, slideway and bearings, and the spring. Install new stronger slideway  +, Fit two new stronger bearings, and put new spring into front hole.  +, Position the new profile lever over the slideway bearings, so that the bearings positively lock into the holes on the profile lever. Ensure that the spring is encapsulated properly. Screw in the new shoulder screw and check for forward-backwards movement on profile lever.  +,