Check Clutch Plate Torque Loading- Still to follow. The Steel Plates fitted all together as C cup Plates is the setting for Maximum load required to Make the Torque Limiter Slip.
Gareth Green
Feb 22 at 6:38 pm

0 Réponse(s)
With the Front Air Fitting Being offset at the Nose seal end , it means The Air pipe from the Blue Triangle Cover and the air fitting need to be re positioned or a longer pipe fitted when placed on a Zx5
Gareth Green
Jan 30 at 2:15 pm

0 Réponse(s)
The sensor gap should also be checked after installation. The maximum Gap to operate is upto 4mm. ideally the sensor should be setup to read closer than this - about 1mm all the way along the Striking plate. A2029 sensor was fitted right on the edge of the 4mm range, and If john gently wobbled the sensor it went on and off. Now lowered
Gareth Green
Dec 5 at 12:44 pm

1 Réponse(s)
470,InF_EjPushH,0,OuF_EjectPush,False,40,3,Eject Push Bar Not Home,True,False,2
Gareth Green
Nov 23 at 10:02 am

0 Réponse(s)
Gareth Green
Nov 21 at 5:01 pm

0 Réponse(s)
Z010 - (Oct 2023) output no.394 in conflict - now sorted - see GG note for 425 to 432
Gareth Green
Oct 19 at 7:11 pm

0 Réponse(s)
All Zx5 machines can do this with the any version of software
Gareth Green
Oct 6 at 11:51 am

1 Réponse(s)
Z055 - ZX4 has been fitted using existing Software setup so Ou_InvDP not used (24v linked to S3 and S4.X308 - Inverter Zero fitted but not used. Uses Drive Run Fwd not using SMOT.
Gareth Green
May 2 at 7:01 pm

0 Réponse(s)
The photo should really show the important bit about the screwdriver - the pozi head
Gareth Green