How to set up the WEG inverters. used on the Transfer crank and Infeed modules.
Author Stuga Engineer | Last edit 28/10/2024 by Gareth Green being drafted ⧼frevu-button-review-label⧽
How to set up the WEG inverters. used on the Transfer crank and Infeed modules.
WEG_Inverter_Setup_WEG_INV.jpg
Date | Photo | |
---|---|---|
2021 | Original Unit fitted due to supply chain issues with Eaton Motor Starters | |
2024 | IO Module added to allow a fault signal to be fed back to control system
see ECN004 WEG Inverter Update - Fault Output ...Additional parameters needed when using IO block
|
Number | Setting | Function | Notes |
---|---|---|---|
P100 | Accel Time | See Below | |
P101 | Decel Time | See Below | |
P133 | 50 | Min Frequency Ref | |
P134 | 50 | Max Frequency Ref | |
P271 | 1 | Set DIx to 24v DC | |
P220 | 1 | Remote Selection | |
P226 | 4 | Remote Rotate Selection | |
P227 | 1 | Remote Run Selection | |
P263 | 4 | DI1 Function (FWD) | |
P264 | 5 | DI2 Function (REV) | |
P265 | 20 | DI3 Function (RESET) | Only Used when IO Module is fitted to front of unit |
P266 | 40 | DI4 Function (ESTOP) | |
P275 | 13 | DO1 Function (FAULT) |
Machine Type | Inverter Location
(Module Panel) |
Motor Location
(Module) |
Motor | P100 | P101 |
---|---|---|---|---|---|
ZX5 | A | A | Infeed Conveyor | 0.1 | 0.1 |
A | A | Infeed Wheel | 0.1 | 0.1 | |
B | C | Crank | 0.5 | 0.1 | |
B | D | Crank | 1.0 | 0.2 | |
B | E | Crank | 0.5 | 0.1 | |
Autoflow Mk4 | B | A | Infeed conveyor | 0.5 | 0.5 |
en
none
0
Published
You entered an invalid page name, with one or many of the following characters :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #