Changing Main Saw Blade

Auteur avatarGareth Green | Dernière modification 3/10/2019 par Gareth Green en cours de rédaction

Introduction

Stuga recommends this blade be changed after 2 weeks of cutting - use the following symptoms to determine if the blade

needs changing:

Awful cutting sound / smell

Profile dragging (sizes too short)

Brown burnt swarf

Smoke coming out of profile end while cutting


...The 500mm blade is sharp and can be awkward to manouver out of the saw, please be careful

Utiliser des vêtements de protection pour les mains
Avertissement des objets pointus et tranchants
Blessure à la main

Étape 1 - Stop Cutting

Make sure you have stopped cutting and nothing on the machine is moving - press an emergency stop button to ensure this.

Étape 2 - Open the door

See the tutorial:

https://stuga.dokit.app/wiki/Autocut_Open_Guard_Doors

Étape 3 - Loosen Blade

Using the saw blade 'C' spanner and the 24mm spanner, loosen and remove the main bolt going through the centre of the saw blade - anti-clockwise to loosen.

Étape 4 - Remove Fastening

Once the bolt is loose; remove the bolt, washer and plate.

...Remember which order they are in, as this is the order they must go back on.

Étape 5 - Remove Blade

Now carefully remove the blade, with this blade being 500mm it will be tight. Ensure you take note of which way the blade spins.

...The blade cutting direction at the top is towards the rear of the machine

Étape 6 - Fit New Blade

Fit the new blade ensuring the teeth are facing the same way it was removed

Étape 7 - Refit Bolt, Plate and Washer

Now fit the plate, washer and bolt ensuring it's tight

Étape 8 - Measure new blade thickness (Kerf)

Measure the thickness of the brand new or sharpened blade - this should be between 3.8mm - 4.1mm

Étape 9 - Update kerf Parameter

Through the winSaw software go into '[F5] Settings' and update the 'Kerf' parameter to what the blade thickness is.

Press 'Save'.

Étape 10 - Close the door

Press '[F10] Reset Saw', now close the main door and ensure it will not open and that the 'Guard' message clears

Étape 11 - Reset Estop

Reset the emergency stop circuit by unlatching emergency stop buttons and pressing the physical blue 'ES RESET' button

Commentaires

Draft