Instructions on how to change a Pneumax valve slice
Auteur Stuga Engineer | Dernière modification 20/09/2019 par Stuga Engineer en cours de rédaction ⧼frevu-button-review-label⧽
Instructions on how to change a Pneumax valve slice
Changing_Pneumax_Valve_slice_IMG_2481.jpg
Please ensure screwdriver is a good fit to avoid wearing the bolt head.
Pull Valve slice off, holding at the bottom and top of the slice. When removing the slice be careful not to bend the pins on the slice.
Also make sure the Valve Gasket piece does not fall out or go missing. This is needed to stop leaks.
Ensure pins line up correctly and are carefully inserted. Push valve slice into position.
When tightening the screws, screw in 2 turns on each of the side until tight to ensure a square fit. Do not over tighten, the bolts will strip easily.
en none 0 Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #