Machine Z109 and A2031 where 1st ones to have this fitted as Standard
Z108 - Has been updated
0 Answer(s)
Z010 - (Oct 2023) output no.394 in conflict - now sorted - see GG note for 425 to 432
0 Answer(s)
STO alarm
Please see https://stuga.dokit.app/wiki/Yaskawa_Inverter_-_Fault_and_Alarm_Output_Functionality
Once wiring changes have been made, change parameter H2-03 to 110. This can be done online via DriveWizard or directly through the
inverter touchpad.
1 Answer(s)
Z055 - ZX4 has been fitted using existing Software setup so Ou_InvDP not used (24v linked to S3 and S4.X308 - Inverter Zero fitted but not used. Uses Drive Run Fwd not using SMOT.
0 Answer(s)
Matthew Preston Also reports on Z094 that P265 had to be set at 0 not 20 to work, Also P266 had to be set at 0 not 40 to work.
These where the values in the 2 other units that where working
0 Answer(s)
Please note : Z094 recently when fitting a new Unit that not all the Parameters above exist Like P275 - Unless it has that module fitted.
0 Answer(s)
Z082 is a ZX5E - No Beam on GX axis - How many links will it need
0 Answer(s)
A2032 and A2033 require different Positions
0 Answer(s)
Once wiring changes have been made, change parameter H2-03 to 110. This can be done online via DriveWizard or directly through the
inverter touchpad.