Due to the SR Axis losing its datum position an additional datum sensor is to be fitted.
Auteur Gareth Green | Dernière modification 14/03/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Due to the SR Axis losing its datum position an additional datum sensor is to be fitted.
TB0390, Fitting, SR, Datum, Sensor TB0390_Fitting_SR_Datum_Sensor_TB0390_Fitting_SR_Datum_Sensor1.jpg
Item Number | Part Number | Description | Qty |
1 | D0015489 | Saw Turntable Sensor Bar | 1 |
2 | D0015490 | Saw Turntable Sensor Flag | 1 |
3 | D0015491 | Saw Turntable Flag Bracket | 1 |
4 | E0000336 | 8mm Threaded Proximity Sensor | 1 |
5 | E0000337 | M8 90° Lead | 1 |
6 | F0000543 | U Bolt 3” with Nuts | 1 |
8 | F0000059 | M8 Washer | 2 |
9 | F0000014 | M6 x 20 SKT CAP SCREW | 2 |
10 | F0000028 | M8 x 50 SKT CAP SCREW | 2 |
Fit U Bolt and Sensor Bar to Table Post on infeed side of saw. See Image for height
Remove 2x M8 screws holding Motor Plate.
Fit Flag and Bracket to Motor Plate with 2x M8 x 50 Screws
Ensure Bracket is far right in the slots and sensor flag is parallel to turntable base.
Check sensor is activated by the flag and stays on when turntable is in maximum position
Drive must be set up to map IO values through to Drive_IO_Status[Axis] array. This is done in 2 steps
1. Add the Digital Inputs State PDO P-0-0801 to S-0-0016 for the SR drive. If a dual axis drive used, ensure you select the correct PDO from the PDO List as there is one for each axis. This is all in the Process Data tab.
2. Link the Digital inputs word to to Drive_IO_Status[9] – simply double click it in the list of IO for the drive