Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component.
Auteur Gareth Green | Dernière modification 20/03/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component.
G Axis, Fault
TB Number: | 238 |
Originator: | Gareth Green |
Machine: | Flowline, Microline, ZX |
Date: | 27/11/13 |
Circulate to: | Service |
Title: | Fault Finding G Axis Stalling |
Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component.
Code | Description |
AX001 | Not Datuming: G Axis |
AX002 | Not Datuming: X Axis |
AX016 | Error Message: Wait 20 Seconds |
AX017 | Gripping position on profile inconsistent |
AX018 | Noise / Vibration from Gripper Stepper Motor |
Code | Description | Tick |
DOCKOFFSET | Check Dockoffset Parameter Correct | |
CHK_AX001 | Check G Axis Leadscrew Bearings and nut tension | |
CHK_AX002 | Check G Axis Beam is Parallel | |
CHK_AX003 | Check G Axis End Stops exist for both forward and reverse travel and are set correctly. What happens if G axis overruns? Any Blockages? | |
CHK_AX004 | Check G Axis Belt Tension and position of joiner block in relation to end of travel | |
CHK_AX005 | Check function of G axis Stepper Motor (Assuming mechanics are all ok) | |
CHK_AX006 | Check SA14 G Axis Stepper drive unit - Blackened connectors / internal D110 Stepper Card / Internal Power Supply / External Fuse | |
CHK_AX007 | Check G Axis Power Cables for continuity on all 4 or s/c to earth | |
CHK_AX008 | Check lubrication of G axis, should move comfortably by hand via toothed belt when motor de-energised | |
CHK_AX009 | Check Function of datum switch and mechanical setting. Is it sticky? Is it set too far out? | |
CHK_AX010 | Check leadscrew coupling grubscrews | |
CHK_AX011 | Check integrity of Step and direction signal cables. Check under heatshrink as excessive heat can melt the cable insulation on original assembly |