Describing how a blunt 10mm tool can cause a datum hole failure
Auteur Gareth Green | Dernière modification 17/01/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Describing how a blunt 10mm tool can cause a datum hole failure
Root_Cause_-_Blunt_Tool_Gripper_Datum_Hole_Failure_Screenshot_2023-01-17_111128.jpg
10mm tool is slightly blunt on piercing end
When machining the datum hole on a ZX5, the profile is only held by the infeed roller clamps and a the infeed datum clamp. If the tool is blunt, it can "grab" the profile and pull it into the machine, therefore changing the datum position and creating inaccuracies
Change the cutter
Check the infeed Datum Rubber Clamp pad exists - Setting Infeed Datum Clamp