Inverter Factory Settings

Cette page contient des modifications qui ne sont pas marquées pour la traduction.

Auteur avatarGareth Green | Dernière modification 24/02/2020 par Gareth Green en cours de rédaction

Pas encore d'image

IMO Cub / Jaguar / VXM / VXR


Parameter Notes Eco ZX Microline VXM Microline CUB Router Drain (CUB) All from M010 / Z026 VXR
F01 Frequency Command Uses Potentiometer on front 4 4 0 4 4 0
F02 Rotation Command Uses relay on 56 & 57 to start rotation 1 1 1 1 1 1
F03 Max Frequency 300 300 300 300 300 300
F04 Base Frequency 300 300 300 300 300 300
F05 Rated Voltage 415 415 415 415 415 415
F07 Accel Time 0.5 0.5 0.5 0.5 0.5 0.4
F08 Decel Time 2.5 2.5 2.5 2.5 2.5 0.2
F09 Torque Boost 6.8 6.8 7 6.8 6.8 6.8
F10 Thermal Overload 1 1 1 1 1 1
F11 Overload Detection Level 4.6 4.6 4.6 4.6 2 4.6
F12 Thermal Time Constant 5 5 5 5 5 5
F14 0 0 0 0 0 0
F15 Frequency Limiter 300 300 300 300 300 300
F16 0 0 0 0 0 0
F18 0 0 0 0 0 0
F20 Dynamic Brake Hz 0 0 0 0 0 0
F21 % Rated Current for Dynamic Brake 0 0 0 0 0 0
F22 Time of Dynamic Brake 0 0 0 0 0 0
F23 0 0 0 0 0 1
F25 0.2 0.2 0.2 0.2 0.2 0.2
F37 1 1 1 1
P02 Motor Rated Power 2.2 2.2 2.2 2.2 0.55 2.2
P03 Motor Rated Current 4.6 4.6 4.6 4.6 2 4.6
P09 Slip Compensation Gain 3 3 3 3 3 3
P99 Motor Selection 4 4 4 4 4
H09 Auto Search Start Mode Set to 2 to search for frequency 0 0 0
E27 1099 1099 1099 1099 1099 1099

Hitachi SJ100 / 200 on Ecolines

SJ100 / 200 Name
A001 Frequency Command 0
A002 Rotation Command 1
A004 Max Frequency 300
A003 Base Frequency 300
F002 Accel Time 0.5
F003 Decel Time 2.5
F001 Frequency Limiter 300

Vacom Inverter

P2.1.1 MinFrequency 300
P2.1.2 Max Frequency 300
P2.1.3 Accel Time 0.4
P2.1.4 Decel Time 0.4
P2.1.5 Current Limit 5
P2.1.6 Motor V 400
P2.1.7 Motor Freq 300
P2.1.8 Motor Speed 18000
P2.1.9 Motor Current 4
P2.1.10 Motor cos 0.75
P2.1.11 Start Function 0
P2.1.12 Stop Function 1
P2.4.2 Brake Chopper Needs Min 63ohm resistor - tested with 160 and 100 in parallel 3

Commentaires

Draft