Input Definition 002 - InA Measure1

Cette page contient des modifications qui ne sont pas marquées pour la traduction.

Auteur avatarGareth Green | Dernière modification 16/04/2020 par Gareth Green en cours de rédaction

Input Definition 002 - InA Measure1

Sommaire

Back To Stuga Machine IO Dictionary - Inputs

Input Definition
Reference 002
Type Input
Code InA_Measure1
Description On-arm flying measuring sensor 1
Used On Autoflow
Function Measuring sensor on the autoflow arm, used to determine the end of the profile when measuring bar lengths at the start of the loading cycle
Sensor Type Laser sensor
Adjustment Adjust for profile position and colour

See Setting Profile Detection Laser Sensor

See Also Input Definition 003 - InA Measure2

TB0189 Narrow Profile Next to Wide on Infeed Table TB0315 Fitting Autoflow Dark Profile Sensor

...If this sensor fails, it can very easily be swapped with sensor no2, simply by swapping the wires. However, this depends on sensor 2 being set up correctly

Commentaires

Draft