Setting the speed of a cylinder requires two people to do it effectively. One to operate the IO screen and one to adjust the speed
Resolution
The IO Service screens on winMulti have a Cycle Timer located at the bottom
If an output is set to on, then the cycle timer increased to a value, the output will cycle on and off at the rate indicated in seconds. This is really useful to accurately set the speed of a cylinder.
Multiple outputs can be set initially, and then all cylinders will fire simultaneously - really useful for setting popup cylinders and checking for air starvation
...Output cycling is only available in setup mode
...Reduce the cycle control back to zero to disable cycling
Solenoid / Solenoid Valves
Some systems (eg Stuertz Infeed table) have "solenoid / solenoid" operated valves instead of the "standard "solenoid / spring" valves. This setup requires two signals / outputs for each valve, one for "out" and one for "home". These valves need a pulsed output to switch one way, then a separate output to fire back again. Unlike a sol / spring valve, the state is maintained on power off
This situation makes testing and setting up more fiddly and complicated, and the need for the cycle control even more acute. Therefore this has been built in to versions front end 6.5.13.0 , back end 6.6001.