Potential root causes of SY axis problems

Symptoms

  • SY Axis / Drive Errors
  • Arrow heads not in centre
  • Cut length inaccuracy on mitre cuts
  • SY axis seized

Potential Root Causes

Root Cause Indicators Tests See Also Pic
SY Linear Bearing Seized Cannot turn the leadscrew (it should turn easily in your fingers) Is the lubrication getting to the bearing? SY Lubrication manifold needs grubscrew "blocker". See ECN005
Common Issue - SY Axis Errors Screenshot 2024-09-03 092255.jpg
Leadscrew seized Cannot turn the leadscrew (it should turn easily in your fingers) Lubrication?
Spacer between motor and motor mount not fitted Coupling inside SY axis bottoms out
D0016381.png
SY axis coupler slipping Intermittent SY axis losing datum position
Centraliser pressure too high
Datum sensor faulty Sensor light flickers

Datum position wanders

Physically mark the zero position.

Using the drive screen repeatedly home the axis and check zero

Datum sensor cable faulty Intermittent cable connection can cause the SY axis datum position to change and wiggle the cables - see if the datum position moves or the sensor light flashes
SY Motor Failure Intermittent problems

SY Motor Quality issues since m/c Z097

SY Motor Cable failure
SY axis drive failure
48v PSU failure Rarely an intermittent fault
48v PSU cable failure