...Clamp settings are quoted in "bar". Newer regulators have a MPa scale where 1 bar=0.1MPa


Machining Centre
Clamp Name Numbering / Ref Factory Setting (bar) Notes
Infeed Top 2.5
Infeed Side 2.5
Outfeed Top 2.5
Outfeed Side 2.5
V Notch 6
ZX5 Infeed Clamp Pad
Gripper Standard 6 Can be reduced if inner webs are crushed, but needs to be strong enough to grip

see TB0257 Fault Finding Gripper Slip

Gripper TruLoc 1
ZX5 Infeed Wheel 1 The weight of the wheel system should be enough to produce enough friction. Too much pressure on this system causes damage to the rollers beneath
Saw Side
Clamp Name Numbering / Ref Factory Setting (bar) Notes
Infeed Top (Low Pressure) 1.5 The infeed top clamp switches between high and low pressure modes. The low pressure setting should keep the profile pressed down as it advanced through the machine
Side Clamp 3
Centralise Clamp 3
Infeed Channel On 1
Infeed Channel off 2


Autoflow Infeed
Clamp Name Numbering / Ref Factory Setting (bar) Notes