|Description=<translate>Installation of the Igus 2500 Energy chain on Stuga machines</translate> | |Description=<translate>Installation of the Igus 2500 Energy chain on Stuga machines</translate> | ||
|Categories=Maintenance | |Categories=Maintenance | ||
Ligne 6 : | Ligne 7 : | ||
There have been reliability problems with the use of the energy chain type "B15" (15.050.048..), prompting the sourcing of a more rigid structural type. The following design points have been taken into account | There have been reliability problems with the use of the energy chain type "B15" (15.050.048..), prompting the sourcing of a more rigid structural type. The following design points have been taken into account | ||
− | * The 2500 type chain from Igus is the correct system for our application. It is a standard type and generally stocked | + | *The 2500 type chain from Igus is the correct system for our application. It is a standard type and generally stocked |
− | * Using the 2500.03 type from this range is has a taller yet narrower cross section, but is ample for the application | + | *Using the 2500.03 type from this range is has a taller yet narrower cross section, but is ample for the application |
− | * A bend radius of 100mm is specified by Beckhoff for the cable, but the decision has been made to reduce down to 55mm. This decision is based on the success / longevity of upgrades done in the field with 55mm radius and the fact that the 100mm bend radius will not fit in all applications. Using the 55mm bend radius allows a | + | *A bend radius of 100mm is specified by Beckhoff for the cable, but the decision has been made to reduce down to 55mm. This decision is based on the success / longevity of upgrades done in the field with 55mm radius and the fact that the 100mm bend radius will not fit in all applications. Using the 55mm bend radius allows a "one size fits all" for all Stuga applications |
− | * The chain should be "Openable Outside" to enable a drag-style application on the inner faces | + | *The chain should be "Openable Outside" to enable a drag-style application on the inner faces |
− | * | + | *Cable separators should be added every 10 links to help keep the cables separate and the Beckhoff cable as central as possible |
− | * Cable tie points on the brackets are 100% essential | + | *Cable tie points on the brackets are 100% essential. These "combs" are a clip on addition |
− | * A rigid chain, coupled with a smaller bend radius | + | *A rigid chain, coupled with a smaller bend radius removes the need for the "anti-rise" trays and the vertical members holding this assembly in the air |
+ | *The Beckhoff cable should be untwisted before feeding into the energy chain<br /> | ||
− | |||
{| class="wikitable" | {| class="wikitable" | ||
|+Components | |+Components | ||
Ligne 26 : | Ligne 27 : | ||
|[https://www.igus.co.uk/product/series-2500 2500.03.055.0] | |[https://www.igus.co.uk/product/series-2500 2500.03.055.0] | ||
|{{#annotatedImageLight:Fichier:Energy Chain 2500.03.055.0.png|0=144px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/a/a0/Energy_Chain_2500.03.055.0.png|href=./Fichier:Energy Chain 2500.03.055.0.png|resource=./Fichier:Energy Chain 2500.03.055.0.png|caption=|size=144px}} | |{{#annotatedImageLight:Fichier:Energy Chain 2500.03.055.0.png|0=144px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/a/a0/Energy_Chain_2500.03.055.0.png|href=./Fichier:Energy Chain 2500.03.055.0.png|resource=./Fichier:Energy Chain 2500.03.055.0.png|caption=|size=144px}} | ||
− | |Energy Chain: Series 2500.03 55mm Bend Radius | + | |Energy Chain: Series 2500.03 55mm Bend Radius |
− | |Supplied in metre units | + | |Supplied in metre units |
|- | |- | ||
|A0001114 | |A0001114 | ||
Ligne 35 : | Ligne 36 : | ||
|Supplied as a Pair | |Supplied as a Pair | ||
Must be the Pivotable type | Must be the Pivotable type | ||
+ | |||
+ | {{Warning|...Do not use the mounting holes in the clip on cable tie addition. This is not strong enough to hold the energy chain}}{{Info|...The 2500 series has a different mounting hole pattern, so the plate that the energy chain is mounted on will need to be redrilled}}<br /> | ||
|- | |- | ||
|A0001112 | |A0001112 | ||
Ligne 52 : | Ligne 55 : | ||
=Installation Flowline - Machining Centre Side= | =Installation Flowline - Machining Centre Side= | ||
+ | <br /> | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | |Upgrade PartNo | ||
+ | | | ||
+ | |- | ||
+ | |Links | ||
+ | | | ||
+ | |- | ||
+ | |Disposal | ||
+ | |Remove the upper "Anti-rise" trays if fitted | ||
+ | |- | ||
+ | |Special Notes | ||
+ | | | ||
+ | |- | ||
+ | |Photos | ||
+ | |{{#annotatedImageLight:Fichier:Energy Chain Installation - 2500 Series Mk3 Igus 1.jpg|0=320px|hash=|jsondata=|mediaClass=Image|type=frameless|align=left|src=https://stuga.dokit.app/images/f/f3/Energy_Chain_Installation_-_2500_Series_Mk3_Igus_1.jpg|href=./Fichier:Energy Chain Installation - 2500 Series Mk3 Igus 1.jpg|resource=./Fichier:Energy Chain Installation - 2500 Series Mk3 Igus 1.jpg|caption=|size=320px}} | ||
+ | |} | ||
=Installation Flowline - Saw Side= | =Installation Flowline - Saw Side= |
Installation of the Igus 2500 Energy chain on Stuga machines
Auteur Gareth Green | Dernière modification 19/02/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Installation of the Igus 2500 Energy chain on Stuga machines
Energy_Chain_Installation_-_2500_Series_Mk3_Igus_1.jpg
There have been reliability problems with the use of the energy chain type "B15" (15.050.048..), prompting the sourcing of a more rigid structural type. The following design points have been taken into account
Part No | Igus Code | Photo | Description | Notes |
---|---|---|---|---|
A0001113 | 2500.03.055.0 | Energy Chain: Series 2500.03 55mm Bend Radius | Supplied in metre units | |
A0001114 | 2030.34PZB | Energy Chain Bracket Set Pivotable With Cable Tie connection | Supplied as a Pair
Must be the Pivotable type ...Do not use the mounting holes in the clip on cable tie addition. This is not strong enough to hold the energy chain
...The 2500 series has a different mounting hole pattern, so the plate that the energy chain is mounted on will need to be redrilled
| |
A0001112 | 25.1.1 | Energy Chain Separator for 2500 Chain | Two separators required every 10 links |
Upgrade PartNo | |
Links | |
Disposal | Remove the upper "Anti-rise" trays if fitted |
Special Notes | |
Photos |