Stuertz Infeed - Check GY Position Parallelism

Auteur avatarGareth Green | Dernière modification 31/01/2023 par Gareth Green en cours de rédaction

Stuertz Infeed - Check GY Position Parallelism Screenshot 2023-01-31 070146.jpg

How to check the parallelism of the Stuertz Infeed - GY axis position to backfence

Introduction

It is important that the parallelism of the GY axis to the backfence is set and maintained along the length of the rack. This tutorial describes how to check this parallelism without the need for measuring equipment

Potential Symptoms of a problem

  • Gripper cannot pick up offcuts
  • Gripper /profile end forced away from backfence
  • Accuracy problems
  • Gripper wobbles after it has released profile

Use the laptop to enable you to control the Service screen whilst inside the infeed table

...You will be inside the danger area of the machine - ensure operators are aware of your situation


Create a spreadsheet or a table to log your results,.

Étape 1 - Ensure a zero GY position at datum

  1. Datum the machine and move GY axis to zero

Étape 2 - Move the GX axis to a position

Étape 3 -

Commentaires

Draft