ZX3/Microline/Flowline ZX3 V Notch Blade Setup This module guides the engineer on how to correctly set the V notch blades

Introduction

The engineer will need a reasonable mechanical knowledge, and a working knowledge of the operation of the machine.

You will need callipers (+/-0.05mm) and an accurate rule


The setting of the V notch blades on a ZX3 revolves around the setting of two groups of parameters:

  • V and W axis positions
  • Blade offsets for each blade

The rough position of V and W axes is set first, then the individual blade offsets are set, and finally a test is run to tweak the accuracy to gain perfection.

There are two “tweaking” parameters for each blade. The two parameters are:

  • Depth offset – how deep into the bar
  • X axis offset – position of point of blade relative to the spindle centreline

Étape 1 - Before You Start

  1. Make sure the Datum is correct first.
  2. V notch blades are not buckled.
  3. Check that the profile width is correct for the profile you are testing.

Étape 2 - Run a VTest

A calibration mnd file has been written to help line up the  x offsets called VTEST. This program creates the following pattern on the bottom of the profile using a 10mm spindle and the notching blades themselves:

Run the VTest operation on a length of large outer frame of at least 1m long. Put the    operation at a position of 500mm.


The pattern allows you to measure the offsets required with calipers.


...Profile is viewed from the bottom face, Basically turn it over when it comes of the transfer table.



Étape 3 - Measure Results for x Offsets

  1. Measure between the VI blade and the edge of the 10mm slot – This value is the xoffsetVI (and also the xoffsetWI).  (We need to add 5mm to the measured Value).  50.33mm
  2. Measure between the VO blade and the edge of the 10mm slot – This value is the xoffsetVO (and also the xoffsetWO).  (We need to add 5mm to the measured Value) 87.59mm
...The 5mm is added becasue this is half the 10mm slot width - thus measuring to the centreline of the slot


Étape 4 - Update the Parameters for xOffsets

  1. Set the xOffsetVI and WI to the new value in params.mul or Measurements in Neuron Settings. THIS VALUE IS ALWAYS POSITIVE
  2. Set the xOffsetVO and WO to the new value in params.mul or Measurements in Neuron Settings. THIS VALUE IS ALWAYS NEGATIVE

xOffsetVO=-87.59
xOffsetVI=50.33
xOffsetWO=-87.59
xOffsetWI=50.33


Vtest is now done and Vcomp now needs to be run to set the depth of blades.