Updating software can be very complicated, so care must be taken and always ensure there is a route to retrace your steps in the event of a failure – with Baldor .mnt files this is easy because each version is a separate file and therefore easy to load the old one back in again
In general, the Baldor (.mnt) software has been designed to be backwards compatible, but there are a few steps that needed to be taken that made this impossible. In these cases, the front end software (winMulti or winSaw) also needs to be updated – you will get an error to tell you that this is the case
Version numbers have always followed a numerical order, so the higher the number, the later the version
Mnt files should always be stored in
c:\multi on MH side – called Multi X.xxx.mnt
c:\saw on Saws or Saw side of flowline – called IgSaw X.xx.mnt
Étape 1 - Acquire latest / relevant software version
Contact Stuga service to download latest version to the machine via teamviewer
On the g:\ drive G:\Builds\Latest Software Versions.
From Dropbox service\Machine Software\
Étape 2 - Copy to correct machine folder
Machine
Folder
Flowline MH side
c:\multi
Flowline Saw Side
c:\saw
Standalone Saw
c:\saw
Ecoline
c:\ecoline
Étape 3 - Open Workbench
Étape 4 - Connect to machine
If this is a brand new setup, you will need to search for the Nextmove card.
If this is an established machine, the connection details are stored in a "project" which should be visible as the build number of the machine
Étape 5 - Close any previous versions of open files
Use File->Close File to close any previous versions that are open
...This clears out the text on the screen and removes the possibility of confusion over which version of the mint file you are using
Étape 6 - Open the new version
Use File->Open to open the new .mnt file version
...Scroll right to the bottom of the editor to check if you have the right version number loaded
Étape 7 - Download and run
Press the play button to download and run
Étape 8 - Exit workbench
Exit Workbench and click Yes to save the project (this means it will auto load the new version mnt file when Workbench is opened next time