Potential root causes of SY axis problems
Auteur Gareth Green | Dernière modification 4/09/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Potential root causes of SY axis problems
R0015037_Bench_Assemble_SY_Assembly_Screenshot_2023-11-21_150208.png
Root Cause | Indicators | Tests | See Also | Pic |
---|---|---|---|---|
SY Linear Bearing Seized | Cannot turn the leadscrew (it should turn easily in your fingers) | Is the lubrication getting to the bearing? | SY Lubrication manifold needs grubscrew "blocker". See ECN005 | |
Leadscrew seized | Cannot turn the leadscrew (it should turn easily in your fingers) | Lubrication? | ||
Spacer between motor and motor mount not fitted | Coupling inside SY axis bottoms out | |||
SY axis coupler slipping | Intermittent SY axis losing datum position | |||
Centraliser pressure too high | ||||
Datum sensor faulty | Sensor light flickers
Datum position wanders |
Physically mark the zero position.
Using the drive screen repeatedly home the axis and check zero |
||
Datum sensor cable faulty | Intermittent cable connection can cause the SY axis datum position to change | and wiggle the cables - see if the datum position moves or the sensor light flashes | ||
SY Motor Failure | Intermittent problems
SY Motor Quality issues since m/c Z097 |
|||
SY Motor Cable failure | ||||
SY axis drive failure | ||||
48v PSU failure | Rarely an intermittent fault | |||
48v PSU cable failure | ||||