[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 19 : | Ligne 19 : | ||
'''Instead, set an optimiser tolerance of 700''', this would mean that the initial 5800 bar would be acceptable therefore getting these 4 sashes out of 4 bars with minimal (200mm) waste per bar. It seems counterintuitive, but in certain circumstances, allowing more waste ends up getting less. | '''Instead, set an optimiser tolerance of 700''', this would mean that the initial 5800 bar would be acceptable therefore getting these 4 sashes out of 4 bars with minimal (200mm) waste per bar. It seems counterintuitive, but in certain circumstances, allowing more waste ends up getting less. | ||
− | {{#annotatedImageLight:Fichier:WinMulti - Advanced Optimisation OptimTolerance700.jpg|0=1094px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/f/fb/WinMulti_-_Advanced_Optimisation_OptimTolerance700.jpg|href=./Fichier:WinMulti - Advanced Optimisation OptimTolerance700.jpg|resource=./Fichier:WinMulti - Advanced Optimisation OptimTolerance700.jpg|caption=700mm Tolerance on Door Sash|size=1094px}} | + | {{#annotatedImageLight:Fichier:WinMulti - Advanced Optimisation OptimTolerance700.jpg|0=1094px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/f/fb/WinMulti_-_Advanced_Optimisation_OptimTolerance700.jpg|href=./Fichier:WinMulti - Advanced Optimisation OptimTolerance700.jpg|resource=./Fichier:WinMulti - Advanced Optimisation OptimTolerance700.jpg|caption=700mm Tolerance on Door Sash|size=1094px}}<br /> |
+ | ====Issue: But we bought in the bars at 5200mm for this Job!==== | ||
− | + | Occasionally, you may have a set of bars which differ in length to the standard. To use them, click on the Reoptimise Icon for the appropriate profile group and enter the new bar length, then click OK, the optimiser will use those bar lengths for that group. This will only affect the current batch. If you wish to change the standard bar length for all batches going forward, see the profile settings screen. | |
− | |||
− | Occasionally, you may have a set of bars which differ in length to the standard. To use them, click on the Reoptimise Icon for the appropriate profile group and enter the new bar length, then click OK, the optimiser will use those bar lengths for that group. If you wish to change the standard bar length see the profile settings screen. | ||
<br /> | <br /> |
This page will explain the options for advanced optimisation
Auteur Stuga Engineer | Dernière modification 6/04/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
This page will explain the options for advanced optimisation
winMulti, Optimisation, Optimise, Reoptimise WinMulti_-_Advanced_Optimisation_Optimisation.jpg
For the vast majority of cases, the standard optimisation will do a good job, but what happens if you have a batch of frames, all of a similar size and the optimiser is leaving you with a group of similar large offcuts, or you are buying in a particular colour of profile which comes in a different bar lengths.
Take for example a group of 4 door sashes 850x2050. With the Optimiser tolerance at 50mm the beginning bar would have 2x850+2x2050=5800, this is out of the 50mm tolerance, the only group of pieces which will (assuming a 6000 bar length) be able within the tolerance is 7x850=5950. this would leave 8x2150 and 1x850 left for future bars, bar 2 would end up as 2x2150 and the remaining 850 for a total of 5050 (950 offcut) and the remaining pieces 6x2050 would have to be 2 per bar leaving 3 offcuts of 1900 and using 5 bars of profile as shown below.
Instead, set an optimiser tolerance of 700, this would mean that the initial 5800 bar would be acceptable therefore getting these 4 sashes out of 4 bars with minimal (200mm) waste per bar. It seems counterintuitive, but in certain circumstances, allowing more waste ends up getting less.
Occasionally, you may have a set of bars which differ in length to the standard. To use them, click on the Reoptimise Icon for the appropriate profile group and enter the new bar length, then click OK, the optimiser will use those bar lengths for that group. This will only affect the current batch. If you wish to change the standard bar length for all batches going forward, see the profile settings screen.
To the Right is the Reoptimize Dialog box, it has 4 options :-
To return to the main page, please click WinMulti Software Operating Guide en none 0
Draft