How to set up datum position on Ecoline
Auteur Gareth Green | Dernière modification 26/11/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
How to set up datum position on Ecoline
datum, mitreoffset WinMulti_-_Datum_Test_Image.png
When an Ecoline is commissioned, the positional accuracy needs to be set up.
These are also useful tests to check if the machine is maintaining positional accuracy
Run 3 tests on the same piece spaced apart by 20mm. Make sure the machine is reinitialised and redatums between each run.
This allows you to see if the position of the holes drifts along the bar
Aim to place the holes at least 400mm in from the bar end
See WinMulti - Datum Test for full instructions
End goal is to produce repeatable datum holes at the correct position from the end of the bar
All gripper positions should be greater than 20 and less than 55
Usually -
A - Slim Outer frame
B - Large Outer Frame
C - Door Profile
Cut \ / pieces around 1000mm
If the position is varying, this highlights a gripping / measuring problem
Check
The position can be adjusted with the parameter
ecoMitreAdjust
After adjustment, run the tests again
Run the tests again with arrowhead end on the test pieces.
If the position is different to the square-end, the position can be adjusted with the parameter