| [version en cours de rédaction] | [version en cours de rédaction] |
(Page créée avec « {{Tuto Details |Description=<translate>Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herrin... ») |
|||
| Ligne 4 : | Ligne 4 : | ||
|Tags=G Axis, Fault | |Tags=G Axis, Fault | ||
}} | }} | ||
| − | <translate>= Technical Bulletin = | + | <translate>=Technical Bulletin= |
{| class="wikitable" border="0" cellspacing="0" cellpadding="0" | {| class="wikitable" border="0" cellspacing="0" cellpadding="0" | ||
| width="111" valign="top" |'''TB Number:''' | | width="111" valign="top" |'''TB Number:''' | ||
| Ligne 15 : | Ligne 15 : | ||
| width="569" valign="top" |Flowline, Microline, ZX | | width="569" valign="top" |Flowline, Microline, ZX | ||
|- | |- | ||
| − | | width="111" valign="top" |'''Date:''' | + | | width="111" valign="top" |'''Date:''' |
| width="569" valign="top" |27/11/13 | | width="569" valign="top" |27/11/13 | ||
|- | |- | ||
| Ligne 25 : | Ligne 25 : | ||
|} | |} | ||
| − | == Detail == | + | ==Detail== |
Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component. | Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component. | ||
| − | == Symptoms == | + | ==Symptoms== |
{| class="wikitable" border="1" cellspacing="0" cellpadding="0" | {| class="wikitable" border="1" cellspacing="0" cellpadding="0" | ||
| width="66" valign="top" |'''Code''' | | width="66" valign="top" |'''Code''' | ||
| Ligne 49 : | Ligne 49 : | ||
|} | |} | ||
| − | == Actions / Checks == | + | ==Actions / Checks== |
{| class="wikitable" border="1" cellspacing="0" cellpadding="0" | {| class="wikitable" border="1" cellspacing="0" cellpadding="0" | ||
| width="102" valign="top" |'''Code''' | | width="102" valign="top" |'''Code''' | ||
| Ligne 104 : | Ligne 104 : | ||
|}</translate> | |}</translate> | ||
{{PageLang | {{PageLang | ||
| + | |Language=en | ||
|SourceLanguage=none | |SourceLanguage=none | ||
|IsTranslation=0 | |IsTranslation=0 | ||
| − | |||
}} | }} | ||
{{AddComments}} | {{AddComments}} | ||
Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component.
Auteur
Gareth Green | Dernière modification 20/03/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component.
G Axis, Fault
| TB Number: | 238 |
| Originator: | Gareth Green |
| Machine: | Flowline, Microline, ZX |
| Date: | 27/11/13 |
| Circulate to: | Service |
| Title: | Fault Finding G Axis Stalling |
Faults on the G axis on a Flowline / ZX / Microline have proved to be a little difficult to trace. It is easy to follow a red herring and change the wrong component.
| Code | Description |
| AX001 | Not Datuming: G Axis |
| AX002 | Not Datuming: X Axis |
| AX016 | Error Message: Wait 20 Seconds |
| AX017 | Gripping position on profile inconsistent |
| AX018 | Noise / Vibration from Gripper Stepper Motor |
| Code | Description | Tick |
| DOCKOFFSET | Check Dockoffset Parameter Correct | |
| CHK_AX001 | Check G Axis Leadscrew Bearings and nut tension | |
| CHK_AX002 | Check G Axis Beam is Parallel | |
| CHK_AX003 | Check G Axis End Stops exist for both forward and reverse travel and are set correctly. What happens if G axis overruns? Any Blockages? | |
| CHK_AX004 | Check G Axis Belt Tension and position of joiner block in relation to end of travel | |
| CHK_AX005 | Check function of G axis Stepper Motor (Assuming mechanics are all ok) | |
| CHK_AX006 | Check SA14 G Axis Stepper drive unit - Blackened connectors / internal D110 Stepper Card / Internal Power Supply / External Fuse | |
| CHK_AX007 | Check G Axis Power Cables for continuity on all 4 or s/c to earth | |
| CHK_AX008 | Check lubrication of G axis, should move comfortably by hand via toothed belt when motor de-energised | |
| CHK_AX009 | Check Function of datum switch and mechanical setting. Is it sticky? Is it set too far out? | |
| CHK_AX010 | Check leadscrew coupling grubscrews | |
| CHK_AX011 | Check integrity of Step and direction signal cables. Check under heatshrink as excessive heat can melt the cable insulation on original assembly |