Ligne 5 : | Ligne 5 : | ||
|Categories=Maintenance | |Categories=Maintenance | ||
|Difficulty=Easy | |Difficulty=Easy | ||
− | |Duration= | + | |Duration=20 |
|Duration-type=minute(s) | |Duration-type=minute(s) | ||
|Tags=Laser Sensor, ZX4, ZX5, Flowline, Commissioning | |Tags=Laser Sensor, ZX4, ZX5, Flowline, Commissioning | ||
Ligne 19 : | Ligne 19 : | ||
{{EPI}} | {{EPI}} | ||
{{Tuto Step | {{Tuto Step | ||
− | |Step_Title=<translate></translate> | + | |Step_Title=<translate>Adjust the "Light Dark"</translate> |
− | |Step_Content=<translate></translate> | + | |Step_Content=<translate>Adjust the "'''Light Dark'''" balance on the sensor. To do this, using a small flat head screwdriver, turn the light dark dial '''clockwise''' until the orange light goes off. Then slowly turn '''anti-clockwise''' until the orange light turns on again, when this happens re-turn a '''little clockwise''' to turn off the orange light.</translate> |
+ | |Step_Picture_00=Commissioning_-_Off-Cut_Laser_Sensor_laser1.PNG | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Adjust Sensitivity</translate> | ||
+ | |Step_Content=<translate>Now adjust the sensitivity. Place an object '''80mm''' away from the sensor. Now adjust the sensitivity until the orange light turns on.</translate> | ||
+ | |Step_Picture_00=Commissioning_-_Off-Cut_Laser_Sensor_laser2.PNG | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Sensor Height Warning</translate> | ||
+ | |Step_Content=<translate>Make sure the height of the sensor is '''ABOVE''' the gaskets on profile.</translate> | ||
+ | |Step_Picture_00=Commissioning_-_Off-Cut_Laser_Sensor_Laser4.PNG | ||
+ | }} | ||
+ | {{Tuto Step | ||
+ | |Step_Title=<translate>Input Laser Measurements</translate> | ||
+ | |Step_Content=<translate>From the 0 Position, measure the distance of each sensor. These should be written down on the sensors. | ||
+ | |||
+ | In the measurements settings (winMulti> Settings > measurements) update each '''offcutSensorX''' parameter with the exact measurements recorded.</translate> | ||
+ | |Step_Picture_00=Commissioning_-_Off-Cut_Laser_Sensor_Laser5.jpg | ||
}} | }} | ||
{{Notes}} | {{Notes}} |
Setting up the laser sensors on the infeed of a Flowline, ZX4 and ZX5.
Auteur Anonymous | Dernière modification 4/10/2019 par Anonymous en cours de rédaction ⧼frevu-button-review-label⧽
Setting up the laser sensors on the infeed of a Flowline, ZX4 and ZX5.
Laser Sensor, ZX4, ZX5, Flowline, Commissioning Commissioning_-_Off-Cut_Laser_Sensor_laser1.PNG
Vimeo
Adjust the "Light Dark" balance on the sensor. To do this, using a small flat head screwdriver, turn the light dark dial clockwise until the orange light goes off. Then slowly turn anti-clockwise until the orange light turns on again, when this happens re-turn a little clockwise to turn off the orange light.
Now adjust the sensitivity. Place an object 80mm away from the sensor. Now adjust the sensitivity until the orange light turns on.
From the 0 Position, measure the distance of each sensor. These should be written down on the sensors.
In the measurements settings (winMulti> Settings > measurements) update each offcutSensorX parameter with the exact measurements recorded.