+ | |Main_Picture=TB0287_Importance_of_Outfeed_Clear_Sensor_287-2.jpg | ||
+ | |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-462,"top":-423,"width":718,"height":589,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":2.56,"scaleY":2.56,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/b/be/TB0287_Importance_of_Outfeed_Clear_Sensor_287-2.jpg","filters":[]}],"height":450,"width":600} | ||
|Description=<translate>The outfeed clear sensor that existed on Mk3 flowlines was not repeated on ZX machines. This leaves the machine vulnerable to crash.</translate> | |Description=<translate>The outfeed clear sensor that existed on Mk3 flowlines was not repeated on ZX machines. This leaves the machine vulnerable to crash.</translate> | ||
|Categories=Maintenance | |Categories=Maintenance | ||
|Tags=OCLEAR, Outfeed Clear, ZX | |Tags=OCLEAR, Outfeed Clear, ZX | ||
}} | }} | ||
− | <translate>= Technical Bulletin = | + | <translate>=Technical Bulletin= |
{| class="wikitable" border="0" cellspacing="0" cellpadding="0" | {| class="wikitable" border="0" cellspacing="0" cellpadding="0" | ||
| width="106" valign="top" |'''TB Number:''' | | width="106" valign="top" |'''TB Number:''' | ||
Ligne 15 : | Ligne 17 : | ||
| width="552" valign="top" |ZX3 / ZX4 | | width="552" valign="top" |ZX3 / ZX4 | ||
|- | |- | ||
− | | width="106" valign="top" |'''Date:''' | + | | width="106" valign="top" |'''Date:''' |
| width="552" valign="top" |20/05/10 | | width="552" valign="top" |20/05/10 | ||
|- | |- | ||
Ligne 25 : | Ligne 27 : | ||
|} | |} | ||
− | == Problem == | + | ==Problem== |
− | The outfeed clear sensor that existed on Mk3 flowlines was not repeated on ZX machines. This leaves the machine | + | The outfeed clear sensor that existed on Mk3 flowlines was not repeated on ZX machines. This leaves the machine vulnerable to crash if one of the following situations occurs: |
· A bar is not correctly ejected onto the transfer table, and the gripper then returns for the next bar | · A bar is not correctly ejected onto the transfer table, and the gripper then returns for the next bar | ||
Ligne 32 : | Ligne 34 : | ||
· A bar is present on the outfeed when the gripper is initialising | · A bar is present on the outfeed when the gripper is initialising | ||
− | == Solution == | + | ==Solution== |
A new outfeed clear sensor has been designed to fit on the third zip gate | A new outfeed clear sensor has been designed to fit on the third zip gate | ||
− | Kit is | + | Kit is R0000312 ZX: Outfeed Sensor |
<br /> | <br /> | ||
− | === Wiring === | + | ===Wiring=== |
Spare cables can be utilised to route the input from the outfeed connection box to the main cabinet. | Spare cables can be utilised to route the input from the outfeed connection box to the main cabinet. | ||
Ligne 46 : | Ligne 48 : | ||
Outfeed Connection Box Pin: 4{{#annotatedImageLight:Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-1.jpg|0=800px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/8/8e/TB0161_Fitting_Outfeed_Clear_Sensor_on_ZX_Machine_161-1.jpg|href=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-1.jpg|resource=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-1.jpg|caption=|size=800px}}{{#annotatedImageLight:Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-2.jpg|0=800px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/c/c0/TB0161_Fitting_Outfeed_Clear_Sensor_on_ZX_Machine_161-2.jpg|href=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-2.jpg|resource=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-2.jpg|caption=|size=800px}}<br /> | Outfeed Connection Box Pin: 4{{#annotatedImageLight:Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-1.jpg|0=800px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/8/8e/TB0161_Fitting_Outfeed_Clear_Sensor_on_ZX_Machine_161-1.jpg|href=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-1.jpg|resource=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-1.jpg|caption=|size=800px}}{{#annotatedImageLight:Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-2.jpg|0=800px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/c/c0/TB0161_Fitting_Outfeed_Clear_Sensor_on_ZX_Machine_161-2.jpg|href=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-2.jpg|resource=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-2.jpg|caption=|size=800px}}<br /> | ||
− | === Cabinet === | + | ===Cabinet=== |
{{#annotatedImageLight:Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-3.jpg|0=800px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/2/2f/TB0161_Fitting_Outfeed_Clear_Sensor_on_ZX_Machine_161-3.jpg|href=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-3.jpg|resource=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-3.jpg|caption=|size=800px}} | {{#annotatedImageLight:Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-3.jpg|0=800px|hash=|jsondata=|mediaClass=Image|type=frameless|align=center|src=https://stuga.dokit.app/images/2/2f/TB0161_Fitting_Outfeed_Clear_Sensor_on_ZX_Machine_161-3.jpg|href=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-3.jpg|resource=./Fichier:TB0161 Fitting Outfeed Clear Sensor on ZX Machine 161-3.jpg|caption=|size=800px}} | ||
Ligne 52 : | Ligne 54 : | ||
Pick up core number 23 from the same cable as X31 – this will exist in the cable trunking. | Pick up core number 23 from the same cable as X31 – this will exist in the cable trunking. | ||
− | Label as X32 and connect to the next hole along from X31</translate> | + | Label as X32 and connect to the next hole along from X31 |
+ | |||
+ | == Setting Up == | ||
+ | See [[Setting Ultrasonic Sensor - Horizontal|https://stuga.dokit.app/wiki/Setting_Ultrasonic_Sensor_-_Horizontal]] to train the ultrasonic sensor | ||
+ | <br /></translate> | ||
{{PageLang | {{PageLang | ||
+ | |Language=en | ||
|SourceLanguage=none | |SourceLanguage=none | ||
|IsTranslation=0 | |IsTranslation=0 | ||
− | |||
}} | }} | ||
{{AddComments}} | {{AddComments}} |
The outfeed clear sensor that existed on Mk3 flowlines was not repeated on ZX machines. This leaves the machine vulnerable to crash.
Auteur Gareth Green | Dernière modification 26/09/2019 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
The outfeed clear sensor that existed on Mk3 flowlines was not repeated on ZX machines. This leaves the machine vulnerable to crash.
OCLEAR, Outfeed Clear, ZX TB0287_Importance_of_Outfeed_Clear_Sensor_287-2.jpg
TB Number: | 161 |
Originator: | Gareth Green |
Machine: | ZX3 / ZX4 |
Date: | 20/05/10 |
Circulate to: | Service |
Title: | 0161 Fitting Outfeed Clear Sensor on ZX Machine |
The outfeed clear sensor that existed on Mk3 flowlines was not repeated on ZX machines. This leaves the machine vulnerable to crash if one of the following situations occurs:
· A bar is not correctly ejected onto the transfer table, and the gripper then returns for the next bar
· A bar is present on the outfeed when the gripper is initialising
A new outfeed clear sensor has been designed to fit on the third zip gate
Kit is R0000312 ZX: Outfeed Sensor
Spare cables can be utilised to route the input from the outfeed connection box to the main cabinet.
Cable number: X32
Outfeed Connection Box Pin: 4
Pick up core number 23 from the same cable as X31 – this will exist in the cable trunking.
Label as X32 and connect to the next hole along from X31
See https://stuga.dokit.app/wiki/Setting_Ultrasonic_Sensor_-_Horizontal to train the ultrasonic sensor