[version en cours de rédaction] | [version en cours de rédaction] |
(Page créée avec « {{Tuto Details |Description=<translate>Following an H&S Incident (0005 – Nova Profile Ejecting), all flowlines and ZXs need to be checked to ensure the “Outfeed Clear... ») |
|||
(Une révision intermédiaire par le même utilisateur non affichée) | |||
Ligne 1 : | Ligne 1 : | ||
{{Tuto Details | {{Tuto Details | ||
+ | |Main_Picture=TB0287_Importance_of_Outfeed_Clear_Sensor_287-1.jpg | ||
+ | |Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":-166,"top":-265,"width":360,"height":480,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":2.26,"scaleY":2.26,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/d/d3/TB0287_Importance_of_Outfeed_Clear_Sensor_287-1.jpg","filters":[]}],"height":450.4559270516717,"width":600} | ||
|Description=<translate>Following an H&S Incident (0005 – Nova Profile Ejecting), all flowlines and ZXs need to be checked to ensure the “Outfeed Clear” sensor is working. The incident proved that if the sensor fails, the outfeed may not be clear and hence the profile can be pushed back through the machine.</translate> | |Description=<translate>Following an H&S Incident (0005 – Nova Profile Ejecting), all flowlines and ZXs need to be checked to ensure the “Outfeed Clear” sensor is working. The incident proved that if the sensor fails, the outfeed may not be clear and hence the profile can be pushed back through the machine.</translate> | ||
+ | |Categories=Maintenance | ||
+ | |Tags=OCLEAR, Outfeed Clear | ||
}} | }} | ||
<translate>= Technical Bulletin = | <translate>= Technical Bulletin = | ||
Ligne 62 : | Ligne 66 : | ||
''' '''</translate> | ''' '''</translate> | ||
{{PageLang | {{PageLang | ||
+ | |Language=en | ||
|SourceLanguage=none | |SourceLanguage=none | ||
|IsTranslation=0 | |IsTranslation=0 | ||
− | |||
}} | }} | ||
{{AddComments}} | {{AddComments}} |
Following an H&S Incident (0005 – Nova Profile Ejecting), all flowlines and ZXs need to be checked to ensure the “Outfeed Clear” sensor is working. The incident proved that if the sensor fails, the outfeed may not be clear and hence the profile can be pushed back through the machine.
Auteur Gareth Green | Dernière modification 26/09/2019 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Following an H&S Incident (0005 – Nova Profile Ejecting), all flowlines and ZXs need to be checked to ensure the “Outfeed Clear” sensor is working. The incident proved that if the sensor fails, the outfeed may not be clear and hence the profile can be pushed back through the machine.
OCLEAR, Outfeed Clear TB0287_Importance_of_Outfeed_Clear_Sensor_287-1.jpg
TB Number: | 287 |
Originator: | Gareth Green |
Machine: | Flowlines, ZX |
Date: | 18/08/2015 |
Circulate to: | Service |
Title: | Importance of Outfeed Clear Sensor |
Following an H&S Incident (0005 – Nova Profile Ejecting), all flowlines and ZXs need to be checked to ensure the “Outfeed Clear” sensor is working. The incident proved that if the sensor fails, the outfeed may not be clear and hence the profile can be pushed back through the machine.
A software update should be installed (contact GG) and the sensor tested for correct function.
The “useOutfeedClear” parameter should be switched on. This software update checks the sensor for the on state before ejecting, and then the off state after ejecting to check that the sensor is functional and not “always off”.
** REMEMBER TO CHECK ON DARK PROFILE if using an opto sensor**
It is possible to upgrade to using an ultrasonic sensor - see https://stuga.dokit.app/wiki/TB0394_Fitting_Ultrasonic_Sensor_to_Flowline_OCLEAR
If the part is faulty, it needs to be replaced with:
1 off E0000231 sensor
1 off E0000375 cable
A ZX3 / 4 machine may not have this part fitted and would need the following kit (see TB0161 for fitting, but ignore software part as this is for Neuron machines).