Energy Chain Identification and Obsolescence : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
 
(9 révisions intermédiaires par le même utilisateur non affichées)
Ligne 2 : Ligne 2 :
 
|Main_Picture=Energy_Chain_Identification_and_Obsolescence_IMG_4564.jpg
 
|Main_Picture=Energy_Chain_Identification_and_Obsolescence_IMG_4564.jpg
 
|Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":3,"top":-127,"width":480,"height":640,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1.18,"scaleY":1.18,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/0/00/Energy_Chain_Identification_and_Obsolescence_IMG_4564.jpg","filters":[]}],"height":449.8409331919406,"width":600}
 
|Main_Picture_annotation={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":3,"top":-127,"width":480,"height":640,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1.18,"scaleY":1.18,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/0/00/Energy_Chain_Identification_and_Obsolescence_IMG_4564.jpg","filters":[]}],"height":449.8409331919406,"width":600}
|Description=<translate>Aid for identifying energy chain types, including obsolescence issues with discontinued products</translate>
+
|Description=<translate>`Aid for identifying energy chain types, including obsolescence issues with discontinued products</translate>
 
|Categories=Maintenance, Specification
 
|Categories=Maintenance, Specification
 
|Tags=igus, energy chain, caterpillar
 
|Tags=igus, energy chain, caterpillar
 
}}
 
}}
<translate><br />
+
<translate>{{Info|...Updated 2024 to remove all references to B15 chain}}
 +
 
 +
 
 +
=X Axis=
 
{| class="wikitable"
 
{| class="wikitable"
|+Energy Chain Use
+
|+
 +
Flowline, Ecoline, ZX3, ZX4 and Microline
 
!Application
 
!Application
!PartNo
+
!Original PartNo
!Supplier Part No
+
!Original Supplier Part No
 
!Height
 
!Height
 
!Width
 
!Width
Ligne 18 : Ligne 22 :
 
!Obsolescence Issues
 
!Obsolescence Issues
 
|-
 
|-
|X axis
+
| rowspan="2" |'''<u>Up to 2020</u>'''<br />
 
 
 
 
Z Axis ZX
 
 
 
 
 
SY Axis Autoflow
 
 
|A0000126
 
|A0000126
A0000158
 
 
|10.4.048.0
 
|10.4.048.0
B15.4.048.0
+
| rowspan="2" |
|
+
| rowspan="2" |
|
+
| rowspan="2" |100
|
 
 
|Non-Openable
 
|Non-Openable
Openable
+
| rowspan="2" |Obsolete from 2019.  
|Obsolete from 2019.  
 
 
Now replaced with A0000169, but not link for link compatible. Needs entire chain replaced
 
Now replaced with A0000169, but not link for link compatible. Needs entire chain replaced
 +
|-
 +
|A0000158
 +
|B15.4.048.0
 +
|Openable
 
|-
 
|-
 
|'''<u>2020 onwards</u>'''
 
|'''<u>2020 onwards</u>'''
  
 
X Axis
 
 
 
Z Axis ZX
 
 
 
V Axis ZX5
 
 
 
SY Axis Autoflow
 
 
|A0001069
 
|A0001069
 
|B15.050.048.0
 
|B15.050.048.0
 
|
 
|
 
|
 
|
 +
|100
 +
|Replacement chain - openable on outside diameter.
 +
'''A0001074''' Horizontal Mount bracket required to allow pivoting
 +
|Now Obsolete - Proved an unreliable replacement
 +
Replace with 2500 series
 +
|-
 +
|2023 Onwards
 +
|A0001113
 +
|2500.03.055.0
 +
|25
 
|
 
|
|ZX5 Z073 onwards
+
|55
Has to be openable to allow Beckhoff plugs through
 
 
 
Two types of bracket available
 
 
 
'''A0001070''' Vertical Mount
 
 
 
'''A0001074''' Horizontal Mount
 
 
|
 
|
 +
|[[Energy Chain Installation - 2500 Series]]
 +
|}
 +
'''Note:''' On long horizontal travels, the first 3 links next to the carriage should be reversed to take the strain from the cable. See [https://assets.mediafly.com/l/yWBMymShgATq Long Travel Drawing]{{#annotatedImageLight:Fichier:Energy Chain Identification and Obsolescence Image.png|0=1094px|hash=ada0b7e70d8293a8f81305077f50cda7|jsondata={"version":"2.4.6","objects":[{"type":"image","version":"2.4.6","originX":"left","originY":"top","left":0,"top":0,"width":2502,"height":1249,"fill":"rgb(0,0,0)","stroke":null,"strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":0.44,"scaleY":0.44,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"crossOrigin":"","cropX":0,"cropY":0,"src":"https://stuga.dokit.app/images/3/39/Energy_Chain_Identification_and_Obsolescence_Image.png","filters":[]},{"type":"wfarrow2line","version":"2.4.6","originX":"center","originY":"center","left":608,"top":194.5,"width":188,"height":201,"fill":"rgba(255,0,0,0)","stroke":"#FF0000","strokeWidth":4,"strokeDashArray":null,"strokeLineCap":"round","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":1,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"x1":-94,"x2":94,"y1":-100.5,"y2":100.5,"x2a":86.18074670061914,"y2a":80.42864534118036,"x2b":74.49546853574513,"y2b":91.35815924663464},{"type":"wfarrow2circle","version":"2.4.6","originX":"center","originY":"center","left":514,"top":94,"width":16,"height":16,"fill":"#aaa","stroke":"#666","strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":0.5,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"radius":8,"startAngle":0,"endAngle":6.283185307179586},{"type":"wfarrow2circle","version":"2.4.6","originX":"center","originY":"center","left":702,"top":295,"width":16,"height":16,"fill":"#aaa","stroke":"#666","strokeWidth":0,"strokeDashArray":null,"strokeLineCap":"butt","strokeDashOffset":0,"strokeLineJoin":"miter","strokeMiterLimit":4,"scaleX":1,"scaleY":1,"angle":0,"flipX":false,"flipY":false,"opacity":0.5,"shadow":null,"visible":true,"clipTo":null,"backgroundColor":"","fillRule":"nonzero","paintFirst":"fill","globalCompositeOperation":"source-over","transformMatrix":null,"skewX":0,"skewY":0,"radius":8,"startAngle":0,"endAngle":6.283185307179586}],"height":546,"width":1094}|mediaClass=Image|type=frameless|alt=Energy Chain Identification and Obsolescence Image.png|align=center|src=/images/thumb/3/39/Energy_Chain_Identification_and_Obsolescence_Image.png/ia-ada0b7e70d8293a8f81305077f50cda7-px-Energy_Chain_Identification_and_Obsolescence_Image.png.png|href=./Fichier:Energy Chain Identification and Obsolescence Image.png|resource=./Fichier:Energy Chain Identification and Obsolescence Image.png|caption=|size=1094px}}<br />
 +
{| class="wikitable"
 +
|+
 +
Autoflow
 +
!Application
 +
!PartNo
 +
!Supplier Part No
 +
!Height
 +
!Width
 +
!Bend Rad
 +
!Notes
 +
!Obsolescence Issues
 
|-
 
|-
 
|X Axis Autoflow
 
|X Axis Autoflow
Ligne 70 : Ligne 75 :
 
|
 
|
 
|
 
|
 +
|100
 
|
 
|
 +
|
 +
|}<br />
 +
{| class="wikitable"
 +
|+
 +
ZX5 up to Z073
 +
!Application
 +
!PartNo
 +
!Supplier Part No
 +
!Height
 +
!Width
 +
!Bend Rad
 +
!Notes
 +
!Obsolescence Issues
 +
|-
 +
| rowspan="2" |'''<u>Up to and including Z072</u>'''<br />
 +
|A0000126
 +
|10.4.048.0
 +
| rowspan="2" |
 +
| rowspan="2" |
 +
| rowspan="2" |100
 +
|Non-Openable
 +
| rowspan="2" |Obsolete from 2019.
 +
Now replaced with A0000169, but not link for link compatible. Needs entire chain replaced
 +
|-
 +
|A0000158
 +
|B15.4.048.0
 +
|Openable
 +
|-
 +
|'''<u>Z073 onwards</u>'''
 +
 +
|A0001069
 +
|B15.050.048.0
 
|
 
|
 
|
 
|
 +
|100
 +
|Replacement chain - openable on outside diameter. Two types of bracket available
 +
Has to be openable to allow Beckhoff plugs through
 +
 +
'''A0001074''' Horizontal Mount bracket required to allow pivoting
 +
|Proved to be unreliable and unstable. Upgrade to 2500 Series
 +
 +
[[Energy Chain Installation - 2500 Series]]
 +
|-
 +
|Z095 Onwards
 +
|A0001113
 +
|2500.03.055.0
 +
|25
 +
|
 +
|55
 +
|
 +
|[[Energy Chain Installation - 2500 Series]]
 +
|}
 +
'''Note:''' On long horizontal travels, the first 3 links next to the carriage should be reversed to take the strain from the cable. See [https://assets.mediafly.com/l/yWBMymShgATq Long Travel Drawing]
 +
<br />
 +
 +
=Z Axis=
 +
<br />
 +
{| class="wikitable"
 +
|+
 +
Flowline
 +
!Application
 +
!PartNo
 +
!Supplier Part No
 +
!Height
 +
!Width
 +
!Bend Rad
 +
!Notes
 +
!Obsolescence Issues
 
|-
 
|-
 
|Z Axis Flowline
 
|Z Axis Flowline
 
|A0000006
 
|A0000006
|[https://uk.rs-online.com/web/p/cable-trunkings/0599522/ SR400-041]
+
|[https://uk.rs-online.com/web/p/cable-trunkings/0599522/ SR400-041] (Cavotec)
 
|35mm
 
|35mm
 
|62mm
 
|62mm
Ligne 82 : Ligne 154 :
 
|
 
|
 
|
 
|
 +
|}
 +
 +
=Ring Trunking=
 +
{| class="wikitable"
 +
|+
 +
!Machine
 +
!PartNo
 +
!Supplier Part No
 +
!Height
 +
!Width
 +
!Bend Rad
 +
!Notes
 +
!Obsolescence Issues
 
|-
 
|-
|Internal Ring
+
|Flowline
|A0000098
+
ZX
|10.2.075.0
+
 
|
+
Microline
|
+
 
|
+
Ecoline
|
+
|D0006310
|
+
| rowspan="2" |10.2.075/220.0
 +
| rowspan="2" |
 +
| rowspan="2" |
 +
| rowspan="2" |75mm
 +
| rowspan="2" |Originally machined in house to give reverse bend radius
 +
 
 +
From 2020,sourced direct from IGUS by D part number
 +
| rowspan="2" |The original 10.2.075 part is no longer available, but the moulded RBR part 10.2.075/220/0 is still made
 
|-
 
|-
|ZX4 V / W Axis
+
|Autoflow
|
+
|D0010318
|
+
|}
|
+
 
|
+
=Autoflow SR Axis=
|
+
{| class="wikitable"
|
+
|+
|
+
!Application
 +
!PartNo
 +
!Supplier Part No
 +
!Height
 +
!Width
 +
!Bend Rad
 +
!Notes
 +
!Obsolescence Issues
 
|-
 
|-
 
|Autoflow SR Axis
 
|Autoflow SR Axis
Ligne 109 : Ligne 208 :
 
|
 
|
 
|
 
|
 +
|}<br />
 +
 +
=Router=
 +
{| class="wikitable"
 +
|+
 +
!Application
 +
!PartNo
 +
!Supplier Part No
 +
!Height
 +
!Width
 +
!Bend Rad
 +
!Notes
 +
!Obsolescence Issues
 
|-
 
|-
|Router  
+
|Router
 
|A0000059
 
|A0000059
 
|132P-II 3.7
 
|132P-II 3.7
Ligne 118 : Ligne 230 :
 
|
 
|
 
|
 
|
|}</translate>
+
|}<br /></translate>
 
{{PageLang
 
{{PageLang
 
|Language=en
 
|Language=en

Version actuelle datée du 25 septembre 2024 à 13:56

Auteur avatarGareth Green | Dernière modification 25/09/2024 par Gareth Green en cours de rédaction

`Aid for identifying energy chain types, including obsolescence issues with discontinued products

...Updated 2024 to remove all references to B15 chain


X Axis

Flowline, Ecoline, ZX3, ZX4 and Microline
Application Original PartNo Original Supplier Part No Height Width Bend Rad Notes Obsolescence Issues
Up to 2020
A0000126 10.4.048.0 100 Non-Openable Obsolete from 2019.

Now replaced with A0000169, but not link for link compatible. Needs entire chain replaced

A0000158 B15.4.048.0 Openable
2020 onwards A0001069 B15.050.048.0 100 Replacement chain - openable on outside diameter.

A0001074 Horizontal Mount bracket required to allow pivoting

Now Obsolete - Proved an unreliable replacement

Replace with 2500 series

2023 Onwards A0001113 2500.03.055.0 25 55 Energy Chain Installation - 2500 Series

Note: On long horizontal travels, the first 3 links next to the carriage should be reversed to take the strain from the cable. See Long Travel Drawing

Energy Chain Identification and Obsolescence Image.png


Autoflow
Application PartNo Supplier Part No Height Width Bend Rad Notes Obsolescence Issues
X Axis Autoflow A0001043 1500.050.100 100


ZX5 up to Z073
Application PartNo Supplier Part No Height Width Bend Rad Notes Obsolescence Issues
Up to and including Z072
A0000126 10.4.048.0 100 Non-Openable Obsolete from 2019.

Now replaced with A0000169, but not link for link compatible. Needs entire chain replaced

A0000158 B15.4.048.0 Openable
Z073 onwards A0001069 B15.050.048.0 100 Replacement chain - openable on outside diameter. Two types of bracket available

Has to be openable to allow Beckhoff plugs through

A0001074 Horizontal Mount bracket required to allow pivoting

Proved to be unreliable and unstable. Upgrade to 2500 Series

Energy Chain Installation - 2500 Series

Z095 Onwards A0001113 2500.03.055.0 25 55 Energy Chain Installation - 2500 Series

Note: On long horizontal travels, the first 3 links next to the carriage should be reversed to take the strain from the cable. See Long Travel Drawing

Z Axis


Flowline
Application PartNo Supplier Part No Height Width Bend Rad Notes Obsolescence Issues
Z Axis Flowline A0000006 SR400-041 (Cavotec) 35mm 62mm 75mm

Ring Trunking

Machine PartNo Supplier Part No Height Width Bend Rad Notes Obsolescence Issues
Flowline

ZX

Microline

Ecoline

D0006310 10.2.075/220.0 75mm Originally machined in house to give reverse bend radius

From 2020,sourced direct from IGUS by D part number

The original 10.2.075 part is no longer available, but the moulded RBR part 10.2.075/220/0 is still made
Autoflow D0010318

Autoflow SR Axis

Application PartNo Supplier Part No Height Width Bend Rad Notes Obsolescence Issues
Autoflow SR Axis


Router

Application PartNo Supplier Part No Height Width Bend Rad Notes Obsolescence Issues
Router A0000059 132P-II 3.7


Commentaires

Draft