[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 29 : | Ligne 29 : | ||
{{Tuto Step | {{Tuto Step | ||
|Step_Title=<translate>Run NetEdit from command prompt</translate> | |Step_Title=<translate>Run NetEdit from command prompt</translate> | ||
− | |Step_Content=<translate>At DOS prompt, ensure you are on drive C: by typing | + | |Step_Content=<translate>At DOS prompt, ensure you are on drive C: by typing<syntaxhighlight> |
+ | c: | ||
+ | </syntaxhighlight>And press enter | ||
− | |||
− | + | type<syntaxhighlight> | |
− | + | netedit | |
− | + | </syntaxhighlight>And press enter</translate> | |
− | |||
− | type | ||
− | |||
− | < | ||
− | |||
− | |||
− | And press enter</translate> | ||
}} | }} | ||
{{Tuto Step | {{Tuto Step | ||
Ligne 77 : | Ligne 71 : | ||
|Step_Content=<translate>Press escape - then Y | |Step_Content=<translate>Press escape - then Y | ||
− | The message: | + | The message:<syntaxhighlight> |
+ | Unable to open params.saw file | ||
+ | </syntaxhighlight> | ||
− | |||
is normal.</translate> | is normal.</translate> |
Using the netedit program to change the IP address of an ACEpc running DOS software
Auteur Gareth Green | Dernière modification 19/09/2019 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Using the netedit program to change the IP address of an ACEpc running DOS software
ACEpc, network, netedit Manual-ACEpc_ACEpclogo.jpg
The ACEpcs use two different systems for connecting a network
At the command prompt, change to drive C: and ensure netedit exists
If the file does not exist, follow the procedure for installing the netedit software using a 'netsetgo' disk
https://stuga.dokit.app/wiki/ACEpc_Installing_netedit_with_NetSetGo_disk
c:
netedit
Build number must be unique. If a flowline saw put an "s" on the end. i.e. F073S
This is supplied by customer. IT department
If testing in house it needs to be on the 192.168.16.xxx range.
e.g 192.168.16.101
If this is for a Flowline - Build Number of Flowline machining center
Otherwise this will be the net NETBEUI name of the pc you are connecting to.
For testing at stuga this will be NAS1
If this is for a Flowline - IP Address of Flowline machining center
Otherwise this will be the IP address of the pc you are connecting to.
For testing at stuga this will be 192.168.16.6
Press escape - then Y
The message:Unable to open params.saw file
is normal.
Ensure the floppy disk is removed and reboot
Success will be seen if the machine boots into Drive D:
If the saw is connected to a flowline, the saw software should run automatically
en none 0 Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #