[version en cours de rédaction] | [version en cours de rédaction] |
Ligne 5 : | Ligne 5 : | ||
|Categories=Maintenance | |Categories=Maintenance | ||
}} | }} | ||
− | <translate>= Components Used = | + | <translate>=Components Used= |
The sensor used on the Mk4 infeed is an E0001526 diffuse sensor, fitted with an E0001064 plug. | The sensor used on the Mk4 infeed is an E0001526 diffuse sensor, fitted with an E0001064 plug. | ||
<br /> | <br /> | ||
Ligne 60 : | Ligne 60 : | ||
{{Info|...This ensures that the profile is in the correct present position for the measuring routine}} | {{Info|...This ensures that the profile is in the correct present position for the measuring routine}} | ||
− | #Using the narrowest, darkest profile you can find, | + | #Using the narrowest, darkest coloured profile you can find, place it at the frontmost edge of the conveyor slots (closest to you). |
+ | #Load the bar using the index button | ||
+ | #Place a white outer frame bar in the 2nd slot behind it, move it to the backfence side of its slot so it is as close to the backfence as possible | ||
#Move the GX axis via Drives tab to the measuring position (around -970mm). | #Move the GX axis via Drives tab to the measuring position (around -970mm). | ||
#Disable the axis by pressing estop | #Disable the axis by pressing estop | ||
− | #Adjust the sensor sensitivity so that it sees the | + | #Adjust the sensor sensitivity so that it sees the coloured profile, but switches off when you move it out of the way. |
− | #Check it | + | #Adjust the sensitivity up until it see the white outer frame in the second slot, then turn down sensitivity gradually until the sensor goes off. |
+ | #Check it works by sliding the coloured profile back and forth to see the sensor light go on and off | ||
<br />Finally, make sure the cabling is cable tied out of the way and there are no loops to catch on stray profile, etc | <br />Finally, make sure the cabling is cable tied out of the way and there are no loops to catch on stray profile, etc |
Notes on Setting the measuring sensors on the Autoflow Mk4 Stuertz Infeed Table
Auteur Gareth Green | Dernière modification 28/02/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Notes on Setting the measuring sensors on the Autoflow Mk4 Stuertz Infeed Table
Stuertz_Infeed_-_Setting_Measuring_Sensor_Screenshot_2023-01-30_200930.jpg
The sensor used on the Mk4 infeed is an E0001526 diffuse sensor, fitted with an E0001064 plug.
E0001526 | E0001064 |
---|---|
Note, this is NOT an E0000498.
The E0001526 hs a more diffuse spot on it and is found to be more suitable for colour and edge detection reliablity |
Plug fitting instructions can be found here
Parameter | Description | Example Value
(dependent on installation) |
Notes |
---|---|---|---|
measureStartPosX | Start position in X axis for measure sensors |
-970 | Should be slightly to machining centre side of profile end stop |
measureStartPosY | Default Gripper Y position for measuring
This can be changed from the default value for specific profiles in the parameter table |
30 | Will only make a difference if the measure sensor is angled |
measureStartPosZ | Default Gripper height for measuring
This can be changed from the default value for specific profiles in the parameter table |
6 | Needs to go as low as possible because the profile sits lower down to the gripper (due to the lifting roller system)
|