Étape 28 - Ensure c:\multi\masterdir.saw is set to two lines of “c:\ddrive\”
Étape 29 - Run winMulti
Étape 30 - Settings-> IO Map stoppable outputs set on correct location (MH / Saw).
Only need to update the ones that are ticked
Étape 31 - Check the inverter program is updated to latest version
This is not needed on a Yaskawa Inverter - follow the process
Étape 32 - Pauses Update
Ps_blowerPulseA=2500
ps_InvAccelTime300Hz=400
ps_InvAccelTime50Hz=400
psInvDecelTime300Hz=400
psInvDecelTime50Hz=400
Étape 33 - zTurretSawType set to “Stuga” (value 1)
Étape 34 - Ensure the latest messages.saw is copied into c:\ddrive\
Étape 35 - Ensure Saw Infeed Gate Alarm not enabled
It is not an alarm and will stop transfer table if opened
Étape 36 - WIDTH SENSOR SETUP
...Only if fitted
Étape 37 - Verify the width sensor is correctly wired in VS fieldbus device feedback
The voltage input is displayed in the “Value” column and should read a low value when clamp is open and above 32000 when clamp closed (CLIS output on)
...Only if fitted
Étape 38 - Map the IO in VS to the correct IO box / channel.
This is iAnalogueInputArray[0].
...Only if fitted
Étape 39 - Set width measure parameters
a. widthMeasureOffset=132.8
b. widthMeasureScale=-0.0030469 <- Note the minus at the beginning
c. widthMeasuringMode=1
...Only if fitted
Étape 40 - Calibrate the widthMeasureOffset
Calibrate the widthMeasureOffset by using CLIS to measure some known profile widths. The measure result can be seen on frmService->Clear Blockages Tab
...Only if fitted
Étape 41 - Ensure all profiles with a rebate
Ensure all profiles with a rebate where CLIS will go underneath have the rebate distance correctly set up in the profile settings. This is all Z profiles. These can be set from the Settings->Profiles Tab
...Only if fitted
Étape 42 - Ensure all profile without a rebate have the rebate measurement set at Zero
...Only if fitted
Étape 43 - Ps_sideClamp is used now as the delay
Ps_sideClamp is used now as the delay for the side clamp before checking the width – this may need to be increased to allow side clamp to close on narrow profiles
Étape 44 - Width measuring can be switched off
If all fails, width measuring can be switched off with widthMeasuringMode=0
Commentaires
ennone0Draft
×
Erreur de saisie dans le nom du tutoriel
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #
Connexion
Pas encore enregistré ? Créez un compte pour profiter de toutes les fonctionnalités du service !