Input Definition 013 to 020 - InA_Pos0On to InA_Pos7On

Sommaire

Back To Stuga Machine IO Dictionary - Inputs

Input Definition
Reference 013-020
Type Input
Code InA_Pos0On, InA_Pos1On, InA_Pos2On , InA_Pos3On , InA_Pos4On , InA_Pos5On , InA_Pos6On , InA_Pos7On
Description Infeed flap activated
Used On Autoflow Mk2

ZX5 Mk1

.. Autoflow Mk1 (A2001-2004) has a conveyor type infeed, not pop-up fingers, so this input does not exist

Function Detects position of flap on the arm of a pop-up infeed table. Position 0 is closest to the backfence
...This numbering is used to future proof the design in case a wider infeed is required with more infeed slots

Sensor Type Proximity Sensor
Adjustment Adjust distance to detected surface - should be <1mm
See Also
Input Definition 013 to 020 - InA PosnOn Image.png
...If this sensor fails, it can very easily be swapped with sensor an "off" sensor, as they are not used. This was an experiment with the design to ensure a sensor is fully "on" to minimise failures, but it was not reliable