Installing a full system software upgrade on a TwinCAT3machine
Auteur Gareth Green | Dernière modification 12/02/2025 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
Installing a full system software upgrade on a TwinCAT3machine
PCEngineer
If a PC fails on a machine in the field and the hard drive data cannot be recovered, it is necessary to replace the PC. This may create a version conflict, as the new PC will have later versions of twinCAT installed than the original
This tutorial outlines the steps required to bring all the machine systems up to the latest level to ensure compatibility
Skip this if updating a good PC
Create a TwinCAT Project from Scratch
This procedure ensures that the front end PC has the latest TwinCAT version, and that the PLC source control program is correctly integrated, meaning the latest PLC code version will be available
If VM exists:
Ensure the VM project is up to date with the target
Multi folder
Get rid of existing c:\multi - copy
Make a copy of the existing c:\multi as a backup
TwinCAT Project
Right click on Solution and save as archive
Backup the mapping file
Latest version of winMulti software is located at
Copy winmulti.exe into c:\multi
Make sure Source control is loaded and set up properly
**Link to process**
Right click->Load Project if not
for both tc3Multi and PLC_Reset
tc3Multi Project->POUs->MAIN
Check remm'ed out machines
Right click-> Toggle network comment state for the correct machine type and blank the others
and check links exist on io blocks
If not 4024, update
POINT OF NO RETURN
Click on the activate icon
On control Systems board
Note previous version
Check on Software versions board to see if any parameter updates are needed
my need params.saw updates