Upgrade Flowline Opto Sensors to Ultrasonic : Différence entre versions

[version en cours de rédaction][version en cours de rédaction]
(Page créée avec « {{Tuto Details |Description=<translate>Upgrading the 3 off opto sensors on a flowline Mk3 infeed table to ultrasonic version</translate> |Difficulty=Medium |Duration=2 |Du... »)
 
 
(4 révisions intermédiaires par un autre utilisateur non affichées)
Ligne 1 : Ligne 1 :
 
{{Tuto Details
 
{{Tuto Details
 +
|Main_Picture=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_0130_-_Copy.jpg
 
|Description=<translate>Upgrading the 3 off opto sensors on a flowline Mk3 infeed table to ultrasonic version</translate>
 
|Description=<translate>Upgrading the 3 off opto sensors on a flowline Mk3 infeed table to ultrasonic version</translate>
 
|Difficulty=Medium
 
|Difficulty=Medium
 
|Duration=2
 
|Duration=2
 
|Duration-type=hour(s)
 
|Duration-type=hour(s)
 +
|Tags=flowline, ultrasonic, infeed, sensor, upgrade
 
}}
 
}}
 
{{Introduction
 
{{Introduction
|Introduction=<translate>With the development of full colour ranges for profiles, the older flowline opto sensors often have trouble "seeing" the darker profiles. An upgrade kit is available (R0019014) to replace the optical sensors with an ultrasonic version</translate>
+
|Introduction=<translate>With the development of full colour ranges for profiles, the older flowline opto sensors often have trouble "seeing" the darker profiles. An upgrade kit is available (R0019014) to replace the optical sensors with an ultrasonic version
 +
 
 +
<br /></translate>
 +
}}
 +
{{Materials
 +
|ItemList={{ItemList
 +
|Item=R0019014
 +
}}
 +
}}
 +
{{EPI}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Kit of Parts</translate>
 +
|Step_Content=<translate></translate>
 +
|Step_Picture_00=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_Flowline_Ultrasonic_2.jpg
 
}}
 
}}
{{Materials}}
 
 
{{Tuto Step
 
{{Tuto Step
|Step_Title=<translate></translate>
+
|Step_Title=<translate>Mechanical Fitting</translate>
 
|Step_Content=<translate></translate>
 
|Step_Content=<translate></translate>
 +
|Step_Picture_00=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_Flowline_Ultrasonic_1_-_Copy.jpg
 +
|Step_Picture_01=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_4469.JPG
 +
|Step_Picture_02=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_4476.JPG
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Wiring</translate>
 +
|Step_Content=<translate>The sensor wiring directly replaces the 3 other sensors</translate>
 +
|Step_Picture_00=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_4473.JPG
 +
|Step_Picture_01=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_4474.JPG
 +
}}
 +
{{Tuto Step
 +
|Step_Title=<translate>Blower</translate>
 +
|Step_Content=<translate>The blower should Tee in to the blower already there for the other offcut measurement sensors</translate>
 +
|Step_Picture_00=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_4478.JPG
 +
|Step_Picture_01=Upgrade_Flowline_Opto_Sensors_to_Ultrasonic_IMG_4479.JPG
 
}}
 
}}
 
{{Notes}}
 
{{Notes}}
 
{{PageLang
 
{{PageLang
 +
|Language=en
 
|SourceLanguage=none
 
|SourceLanguage=none
 
|IsTranslation=0
 
|IsTranslation=0
|Language=en
 
 
}}
 
}}
 
{{Tuto Status
 
{{Tuto Status
 
|Complete=Draft
 
|Complete=Draft
 
}}
 
}}

Version actuelle datée du 31 mars 2020 à 16:02

Auteur avatarGareth Green | Dernière modification 31/03/2020 par Stuga Engineer en cours de rédaction

Upgrade Flowline Opto Sensors to Ultrasonic IMG 0130 - Copy.jpg

Upgrading the 3 off opto sensors on a flowline Mk3 infeed table to ultrasonic version

Introduction

With the development of full colour ranges for profiles, the older flowline opto sensors often have trouble "seeing" the darker profiles. An upgrade kit is available (R0019014) to replace the optical sensors with an ultrasonic version


Étape 1 - Kit of Parts



Étape 2 - Mechanical Fitting


Étape 3 - Wiring

The sensor wiring directly replaces the 3 other sensors


Étape 4 - Blower

The blower should Tee in to the blower already there for the other offcut measurement sensors


Commentaires

Draft