Alignment details for base and 1st stage ejector
Auteur Gareth Green | Dernière modification 16/02/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Alignment details for base and 1st stage ejector
R0015330_Fit_1st_stage_Ejector_and_Level_Base_Screenshot_2023-10-20_115525.png
Tools Required
Standard hex key set
300mm engineers level
Parts Required
D0004014 Ejector Tie Bar x 2
D0004328 Rod Base (5303) x 1
H0004629 Shaft 20mm: 754 Ejector x 2
R0000570B Bench Assemble 1st stage Ejector and Level Base x 1All bolts to have Loctite 243 adhesive applied unless otherwise stated
All Threaded Pneumatic connections to have Loctite 570 applied
All bolts to be pen marked once adhesive applied and correct tension added
Use engineers level at indicated points to set base level
Adjust using jacking screws on support brackets
use engineers level to check level of eject assembly
Adjust base evenly to maintain base level , to adjust eject shafts
End block level should also be checked for level and adjusted to be correct
Adjusting brackets should be removed individually once all settings are complete
remove one bracket and replace with 2nd m8 fixing bolt. Monitor base position with level when removing brackets and adjust to correct if movement occurs