Additional root causes that can affect arrow head accuracy
Auteur Gareth Green | Dernière modification 17/08/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Additional root causes that can affect arrow head accuracy
TM016_Arrow_Head_Adjustment_on_Saw_image9.jpg
Arrow head setup on a Stuga Sawing centre (not Autoflow) should be simple - the sawing fences centralise around the profile
If the arrow heads are varying or different on one profile to another, there must be other root causes involved - use this checklist to see if
Potential Root Cause | Symptoms | Checks |
---|---|---|
Swarf or offcut stuck stopping the centralise getting to position | All arrow heads out by the same amount on one bar or a set of bars in order, then correct again
Arrow heads out by a long way (>5mm) towards front of machine Mitre cut lengths also short (not long) |
Check the side fence reaches the profile when centralising |
Z Support not active for profile
Z support incorrectly set for profile rebate |
On Z profiles, Bottom arrow head is different to top
First or last arrow head on bar is different to others |
Check Z support settings
Manually check how the Z profile is clamped with the Z support out |
Profile not symmetrical | One profile incorrect but others ok | See TB0395 How To Test T transom Symmetry |
Arrow head offsets (fiddle factors) historically set | Some arrow heads correct, others not, but fixed pattern, not varying along bar length | Reset all ofsets to zero before starting |
Side Clamps not parallel | First or last arrow head on bar is different to others | Check front fences are parallel with the rear |
Potential Root Cause | Symptoms | Checks |
---|---|---|
SY axis needs lubricating | Arrow heads varying with no pattern, change after redatum
SY axis stalling and has following errors |
Check SY axis moves full range of movement by hand and via drives screen |
SY axis sensor not functioning correctly | Arrow heads varying with no pattern, change after redatum | |
SY Axis Datum is wrong | All arrow heads out by same amount | Check and double check offsets
Check repeatability of SY axis datum visually (mark a line and repeatedly ..You have to ask yourself why the SY axis datum position has changed - there has to be a root cause. Simply changing the parameter will mask the real problem and therefore guaranteed to return again minutes or days later
|