R0015300 Rotary Ring pneumatic test

Auteur avatarGareth Green | Dernière modification 11/12/2023 par Gareth Green en cours de rédaction

Étape 1 - Connect air feed

Compressed air feed needs connecting to main 6mm blue feed pipe to ring.

Use adapter to enable safe connection via PCL coupling and probe

...Spindles may move when air fee dis connected. Ensure no parts or persons are in the areas of movement



Étape 2 - Check for air leaks

When air is connect to rotary ring, attention should be paid to any audible air leaks. If any are present, identify source and rectify

Étape 3 - Home positions

1 When air is connected, all cylinders should be in a contracted state. This is their home position



Étape 4 - Home position correction

If correct practice has been followed, only the double slide cylinder will have the possibility of being at the incorrect home position . This is easily rectified


1 Image shows incorrect position when air has been connected to mains supply


2 To rectify, disconnect mains air feed and swap the two indicated pipes at the stem elbows


3 Reconnect air and confirm correct home position is now achieved


Étape 5 - Manual valve activation

Valves can be activated manually by the control button. When pressed, the valve will fire the associated cylinder to its active position .


1 Manual valve activation button



Étape 6 - Test single slide bases

4 off


Check that when valve is activated, spindle assembly goes to the position shown. Fire valve a few times to check movement is consistent. Cylinder speeds and cushioning will be set at a later point



Étape 7 - Test double slide bases

4 off


Check that when valve is activated, spindle assembly goes to the position shown. Fire valve a few times to check movement is consistent. Cylinder speeds and cushioning will be set at a later point


1 Single stage cylinder activated by lower valve , see image for details


2 Double stage cylinder activated by upper valve , see image for details



Étape 8 - Disconnect air

Once pneumatic testing is complete disconnect the air supply

Commentaires

Draft