Installation procedure for Autoflow Mk4
Auteur Gareth Green | Dernière modification 18/08/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Difficulté
Hard Difficile
Installation procedure for Autoflow Mk4
Introduction
General Procedure is
- Prepare Area
- Unload from Transport
- Locate and level infeed table
- Locate, level and align machining module
- Locate, level and align outfeed table
- Fix to floor
- Locate waste conveyor system
- Guard fencing assembly
Étape 2 - Unload from Transport
Étape 3 - Locate and level infeed table
Étape 4 - Locate, level and align machining module
Machining centre distance to infeed between frames =
Étape 5 - Reattach Eject system
...Check the datum sensor gap is 0.5-1mm from the carriage for reliable datuming
Étape 6 - Locate, level and align outfeed table
Machining centre to outfeed distance between frames =
Étape 8 - Locate waste conveyor system
Étape 9 - Guard fencing assembly
Étape 10 - Connect Services