RMAUT04 Autoflow Reduce Guard to Floor Height

Auteur avatarGareth Green | Dernière modification 23/01/2022 par Gareth Green en cours de rédaction

Modification to reduce the guard to floor height <180mm

Objectives

To comply with BS EN ISO 13857 the gap below a guard must be less than 180mm to prevent access for the whole body. The original installation will be higher than this, so the objective is to make this area of the machine compliant.

The guards on the Autoflow are fastened in a slot with 3 bolts and can be simply adjusted to reduce this height.

The objective is to reduce the height to 180mm or less.


RMAUT04 Autoflow Reduce Guard to Floor Height Image1.png


RMAUT04 Autoflow Reduce Guard to Floor Height Image2.png

This change will reduce the height of the guard, however this will still give an overall height of at least 1800mm.

Use a pair of spacers, possibly made from uPVC profile to easily set the height for each panel.

Completion

This modification is expected to take no longer than 1 hour to complete.

Completion is when:

  • All guards set to >=180mm high
  • Entry in Monday Retrofit Compliance board
    1. Entry in comments section to log you have completed it and any difficulties encountered
    2. Update the Status
    3. Add time taken
    4. Add phots to evidence work in photos column
Monday Retrofit Compliance Evidence.png


Compliance Data

According to BS EN ISO 13857, section 4.2.2.2, Table 1 (assuming slight injury and low severity),


RMAUT04 Autoflow Reduce Guard to Floor Height Image 3.png


Hazard Height = 1400mm, safe distance to hazard 100mm. In this case the hazard is 500mm away