RMAUT01 Infeed Light Beam and Additional Guarding

Auteur avatarGareth Green | Dernière modification 22/01/2022 par Gareth Green en cours de rédaction

Pas encore d'image

Fit safety lightcurtain to reduce operator reach over limitation

Objective

To improve the Autoflow operator safety by

  • Increasing the distance between the operator and the hazard (gripper arm) to >1500mm to comply with BS EN ISO 13857. Achieved by by adding buffer bar extensions to the current infeed arms and fully guarding any open access area
  • Adding a light curtain that will be interrupted when the operator enters the walk-in areas. This will be connected to the safety circuit
  • Adding a side guard to prevent operator reach around
  • Adding front guarding under infeed arms to prevent operator access through table


Completion

This modification is expected to take no longer than 4 hours to complete.

Completion is when:

  • All components added
  • Light curtain wired in
  • Testing integrity of light curtain system - sign off on Device Magic form required
  • Entry in Monday Retrofit Compliance board
    1. Entry in comments section to log you have completed it and any difficulties encountered
    2. Update the Status
    3. Add time taken
    4. Add phots to evidence work in photos column
Monday Retrofit Compliance Evidence.png


Commentaires

Draft