Modification to reduce the guard to floor height <180mm

Sommaire

To comply with BS EN ISO 13857 the gap below a guard must be less than 180mm to prevent access for the whole body.

The guards on the Autoflow guarding are fastened in a slot and can be simply adjusted to reduce this height.


RMAUT04 Autoflow Reduce Guard to Floor Height Image1.png


RMAUT04 Autoflow Reduce Guard to Floor Height Image2.png

This change will reduce the height of the guard, however this will still give an overall height of at least 1800mm.

According to BS EN ISO 13857, section 4.2.2.2, Table 1 (assuming slight injury and low severity),


RMAUT04 Autoflow Reduce Guard to Floor Height Image 3.png


Hazard Height = 1400mm, safe distance to hazard 100mm. In this case the hazard is 500mm away