How to solve a Timeout on V Blade Out or Home Error
Auteur Gareth Green | Dernière modification 19/10/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
How to solve a Timeout on V Blade Out or Home Error
Timeout, VO blade, VI Blade
Fault codes
001 Timeout on VI Blade Home
002 Timeout on VI Blade Out
003 Timeout on VO Blade Home
004 Timeout on VO Blade Out
005 Timeout on WI Blade Home
006 Timeout on WI Blade Out
007 Timeout on WO Blade Home
008 Timeout on WO Blade Out
This means that the Inputs at the top or bottom stroke of the V notching cylinders are not being made within a set number of seconds of the Output Valve and being operated (timeout).
Message | V Notch Station | Input Reference | Valve Reference |
---|---|---|---|
Timeout on VI Blade Home | Front Infeed Side | VICTH | Y32 VICUT |
Timeout on VI Blade Out | Front Infeed Side | VICTO | Y32 VICUT |
Timeout on VO Blade Home | Front Outfeed Side | VOCTH | Y33 VOCUT |
Timeout on VO Blade Out | Front Outfeed Side | VOCTO | Y33 VOCUT |
Timeout on WI Blade Home | Rear Infeed Side | WICTH | Y36 WICUT |
Timeout on WI Blade Out | Rear Infeed Side | WICTO | Y36 WICUT |
Timeout on WO Blade Home | Rear Outfeed Side | WOCTH | Y37 WOCUT |
Timeout on WO Blade Out | Rear Outfeed Side | WOCTO | Y37 WOCUT |
You can go into F5 – Settings then find Tab for Alarms and add an extra 2 seconds onto Alarms no.2 and No.4– Make 80 into 100 on the Timeout column. I would have thought 10 seconds is plenty of time for a V notch blade to travel all the way from the top to the bottom through the Profile unless the Blades are really Blunt or the Hydrocheck is not adjusted correctly.
2,VICTO,0,VICUT,True,80,3,Timeout on VI Blade Out,True,False,0
4,VOCTO,0,VOCUT,True,80,3,Timeout on VO Blade Out,True,False,0
I hope this makes sense and will Highlight the issue for you.
If the Input is made within the 80 (8 seconds) the Blade will retract and then go back up.
You good have Faulty Air valves (water damage) that are not switching On and have a delay this will cause you the same issue.
If the Input is made after the 8 seconds you will get the Message and if the input is Made then Pressing Start will override the Alarm. en none 0
Draft