A description of the sclick file and error codes
Auteur Gareth Green | Dernière modification 25/06/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
A description of the sclick file and error codes
sclick
When winSaw first runs, there are a lot of initialisation files to load and a lot of potential areas for the software to fail.
To help identify where these problems are, the software outputs a number to a file called "sclick.txt" which logs what it is attempting to do
Knowledge of these codes will allow you to trace what a startup / initialisation problem could be, as the final code in the list will be the issue that caused the initialisation to fail
Code | Description | Notes |
---|---|---|
1 | Check if App already running | |
2 | Open main screen and locate | |
3 | Set interval timer | |
4 | Set front end version | |
5 | initialise main program | |
51 | Load Master Dir text | |
52 | Create internal variables | |
53 | Load Profiles | |
54 | Load colours | |
5401 | Load AH Adjustments | |
541 | Create machine database | |
333 | Load Offcuts | |
55 | Load Gaps | |
56 | Load messages | |
57 | Load IO Definition | |
575 | Load laser correction file | |
58 | Set directory structure | |
59 | Housekeep old "finished" autoqueue batches | |
591 | Housekeep old archive files | |
592 | Start Autoqueue | |
6 | Add Initialise Button | |
11 | Initialise pressed | |
12 | initialise machine |