Error message appears on screen to operator. “Idle Time Overrun – Contact Stuga”. It is not clear what this message means or what could be the root causes.
Auteur Gareth Green | Dernière modification 27/05/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Error message appears on screen to operator. “Idle Time Overrun – Contact Stuga”. It is not clear what this message means or what could be the root causes.
idle, time, overrun TB0331_Idle_Time_Overrun_Message_PHOTO-2020-05-26-07-32-02.jpg
TB Number: | 331 |
Originator: | Gareth Green |
Machine: | Flowlines / ZX /Microlines – Baldor Controllers |
Date: | 28/11/16 |
Circulate to: | Service; |
Title: | Idle Time Overrun Error Message |
Error message appears on screen to operator. “Idle Time Overrun – Contact Stuga”. It is not clear what this message means or what could be the root causes.
The error is created by the Baldor controller on any one of the servo controlled axes (X, Y or Z) when the axis does not quite get to its intended position. More specifically, when the axis is nearly there, but within the “FolErr” distance (one of the axis setup parameters).
Treat it the same way you would a Stall or Following Error, except you have the knowledge that the axis is very nearly at its position.
Potential Root Causes |
Z axis travel limited on V notch move to 100mm – swarf packed under bearing block |
Spindle not spinning as it hits profile – x axis cannot move |
Blunt tool in spindle |
Plunge speed too fast on a spindle |
The test and subsequent alarm for this error comes following investigations into spindle failures in 2015. A failure mode was discovered where the spindle could plunge with a “Speedy” operation, but due to various reasons, the spindle was not spinning when it hit the profile.
A fault detection system was introduced to timeout if the controller was waiting for idle, yet the axis was within its following error distance. Instead of waiting forever, an “Idle Time Overrun” error is thrown, which ensures any spindle power is switched off.