Input Definition 013 to 020 - InA_Pos0On to InA_Pos7On
Auteur Gareth Green | Dernière modification 27/04/2020 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Input Definition 013 to 020 - InA_Pos0On to InA_Pos7On
InA_Pos, X013 Input_Definition_013_to_020_-_InA_PosnOn_Autoflow_Infeed_Pos_Sensors.jpg
Back To Stuga Machine IO Dictionary - Inputs
Reference | 013-020 |
Type | Input |
Code | InA_Pos0On, InA_Pos1On, InA_Pos2On , InA_Pos3On , InA_Pos4On , InA_Pos5On , InA_Pos6On , InA_Pos7On |
Description | Infeed flap activated |
Used On | Autoflow, ZX5 Mk1 |
Function | Detects position of flap on the arm of a pop-up infeed table. Position 0 is closest to the backfence ...This numbering is used to future proof the design in case a wider infeed is required with more infeed slots
|
Sensor Type | Proximity Sensor |
Adjustment | Adjust distance to detected surface - should be <1mm |
See Also |