Input Definition 013 to 020 - InA PosnOn

Auteur avatarGareth Green | Dernière modification 27/04/2020 par Gareth Green en cours de rédaction

Input Definition 013 to 020 - InA_Pos0On to InA_Pos7On

Sommaire

Back To Stuga Machine IO Dictionary - Inputs

Input Definition
Reference 013-020
Type Input
Code InA_Pos0On, InA_Pos1On, InA_Pos2On , InA_Pos3On , InA_Pos4On , InA_Pos5On , InA_Pos6On , InA_Pos7On
Description Infeed flap activated
Used On Autoflow, ZX5 Mk1
Function Detects position of flap on the arm of a pop-up infeed table. Position 0 is closest to the backfence
...This numbering is used to future proof the design in case a wider infeed is required with more infeed slots

Sensor Type Proximity Sensor
Adjustment Adjust distance to detected surface - should be <1mm
See Also
Input Definition 013 to 020 - InA PosnOn Image.png
...If this sensor fails, it can very easily be swapped with sensor an "off" sensor, as they are not used

Commentaires

Draft