Solving Intermittent Nextmove Issues
Auteur Gareth Green | Dernière modification 2/12/2019 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
Solving Intermittent Nextmove Issues
Nextmove, SetLink, fParameter, setXXXlink
TB Number: | 317 |
Originator: | Gareth Green |
Machine: | All |
Date: | 12/08/16 |
Circulate to: | Service |
Title: | Fault Finding Nextmove Controller Errors |
A common issue on any machine controlled by a Nextmove Controller is a loss of the communication channel between front-end (The winMulti program) and back-end (the nextmove controller). The fault symptoms are an error message box on the front screen that can often look a bit technical:
Fatal Error: Cannot Write fParameter data. Device Driver Failed
Fatal Error: Cannot read Inverter data
Fatal Error: Error Downloading Starter recipe
Cannot Read Firmware on Ethernet. Must use a setXXXLink function
Often, this is an intermittent problem which makes it hard to pin-point. The only method to finding the fault is to replace or try each item in turn in the root causes until the problem stops happening.
Root Cause | Solution | |
1. | PC USB port fault | Try plugging into a different USB port |
2. | USB cable / connections between PC and Nextmove | Try a different USB cable |
3. | Nextmove card fault | Try different Nextmove card |
4. | 24v Short circuit | Add a separate 24v PSU to connector X1. This will not solve the root cause, but will at least help fault finding by elimination |
5. | PC Failure | Replace PC |