CX5120 Beckhoff PC Setup
Auteur Gareth Green | Dernière modification 31/07/2023 par Stuga Engineer en cours de rédaction ⧼frevu-button-review-label⧽
Pas encore d'image
CX5120 Beckhoff PC Setup
Beckhoff, CX5120, Setup
Plug in the Ethernet, DVI, Keyboard and Mouse to the Beckhoff PLC. This can be done on a machine (as shown) or before installation (without etherCAT or slices).
Go to Internet Explorer and search "www.teamviewer.com/en/download/windows/". Scroll down to TeamViewer Host and click on 'Download Host', when prompted press 'Run' to start download. Make sure download is of the most recent version.
Change name to the machine name that the PC is for (i.e. F010B)
Change time and date. For this, go to the bottom right date of the PC and right click the time and date. Go to ‘Adjust time and date’ and select internet time. Press ok.
Go to Control Panel then ‘Region and Language’ and select ’English (United Kingdom)’.
Go to ‘Network and Sharing Centre’ then ‘Change Adaptor Settings’. Rename the area connection 1 to ‘EtherCAT’ and local area connection 2 to ‘Ethernet’. This relates back two the two network ports on the Beckhoff machine.
When the Beckhoff machine starts, internet explorer will load. The web page will contain a 'password wizard' use this wizard to change the password from "1" to "Stuga001".