This involves setting a "window" for a minimum and maximum range when mounted horizontally

Video d'introduction

Étape 1 - Ensure there is 30mm clearance from sensor to profile

The sensor will not work unless there is 30mm clearance to minimum position



Étape 2 - Place Profile at minimum position

Usually with profile against backfence



Étape 3 - Press and hold button until lights flash

Around 3 seconds



Étape 4 - Place profile at maximum position

On an Ecoline, around 60mm



Étape 5 - Press and hold until lights stop flashing



Étape 6 - Test with profile

Ensure it turns off and on in the set window