Introduction
This involves setting a "window" for a minimum and maximum range when mounted horizontally
Étape 1 - Ensure there is 30mm clearance from sensor to profile
The sensor will not work unless there is 30mm clearance to minimum position
Étape 2 - Place Profile at minimum position
Usually with profile against backfence
Étape 3 - Press and hold button until lights flash
Around 3 seconds
Étape 4 - Place profile at maximum position
On an Ecoline, around 60mm
Étape 5 - Press and hold until lights stop flashing
Étape 6 - Test with profile
Ensure it turns off and on in the set window