Bench assembly details for guards and doors
Auteur Gareth Green | Dernière modification 10/01/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Bench assembly details for guards and doors
R0015321_Bench_Assemble_Guards_and_Doors_Screenshot_2023-11-01_175538.png
Tools Required
Standard hex key set
Standard spanner set
Dymo label printer
Parts Required
C0001152 Camera: HikVision DS-2CD2343G0-I-2.8mm x 3
C0001239 Micro SD Card 32Gb Class 10 x 3
D0007643B Perspex Glazing - Door x 4
D0007644B Machining Centre Door 1 x 2
D0007645B Machining Centre Door 2 x 2
D0007654B Perspex Glazing - Front Guard MkB x 1
H0015747 8mm diameter rod x 1 ( in process of changing to D0015747 x 4 )
M0000036 Sign - Ear Protection x 1
M0000201 T Handle Cabinet Lock x 2
Use locktite 243 on all fasteners
Use loctite 572 on all threaded pneumatic connection
Pen mark all fasteners to show finalised
Fit Pre assembled lights to roof panel
Ensure nyloc nuts are used to back of fixings on light assemblies
Fit cable tie bases
Attach Cables from lights to tie bases
Fit Large clear stuga sticker to top face of roof
fit central and facing infeed
Fit C0001239 Micro SD Card 32Gb Class 10 x 1 to camera before mounting
Fit camera to top guard using 3 off M4 x 12 socket caps , and back off with M4 dome nuts and M4 A form washers
Ensure camera is fitted the correct orientation. Camera will have a 'UP' marked on body. This must be at the top
Camera must be fitted to top corner of front guard closest to Module F saw unit
Fit C0001239 Micro SD Card 32Gb Class 10 x 1 to camera before mounting
Fit camera to rear panel using 3 off M4 x 12 socket caps , and back off with M4 dome nuts and M4 A form washers
Ensure camera is fitted the correct orientation. Camera will have a 'UP' marked on body. This must be at the top