Mounting details for SR axis flag and sensor
Auteur Gareth Green | Dernière modification 4/12/2023 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Mounting details for SR axis flag and sensor
R0015085_Mount_SR_Datum_Sensor_and_Flag_Screenshot_2023-10-20_075214.png
Tools Required
Standard Hex key set
Standard spanner set
Parts required
D0015489 Saw Turntable Sensor Bar x 1
E0000336 Sensor: M8; 2mm, PNP N/O, M8 conn x 1
M0001165 U bolt 3nb M12 BZP x 1
All bolts to have Loctite 243 adhesive applied unless otherwise stated
All Threaded Pneumatic connections to have Loctite 570 applied
All bolts to be pen marked once adhesive applied and correct tension added
Attach u bolt and sensor bracket on infeed mounting pillar
Fix with M12 nuts and M12 A form washers
Ensure bracket is mounted square to pillar base, only apply light tension to M12 nuts
Fit E0000336 sensor to assembly
Leave 10mm protrusion from top of bracket as shown
Ensure shakeproof washer is fitted under sensor nut
Set Height of U bolt bracket assembly in relation to flag on saw motor plate, to set sensor withing +- 2mm of flag
Set sensor height to minimal clearance (-1mm )
Check gap is consistent on full travel over sensor flag when head is rotated
Finalise M12 nuts and ensure U bolt assembly is mounted true as to not impact on side sheet guarding panel when fitted later
Check sensor position has not moved
once finalised, double check correct operation of sensor.
Sensor should be within -1mm at all points of travel onto SR axis datum flag. Sensor should NEVER be in contact with flag at any point of movement