Setting an ultrasonic sensor mounted vertically
Auteur Gareth Green | Dernière modification 18/04/2024 par Gareth Green en cours de rédaction ⧼frevu-button-review-label⧽
Durée
5 minute(s) minute(s)
Setting an ultrasonic sensor mounted vertically
Durée
5 minute(s) minute(s)
ultrasonic, ecoline, setting, infeed
Setting_Ultrasonic_Sensor_-_Horizontal_IMG_1313.jpg
Introduction
This involves setting a "window" for a minimum and maximum range when mounted horizontally
Étape 1 - Ensure there is 30mm clearance from sensor to profile
The sensor will not work unless there is 30mm clearance to minimum position
Étape 2 - Place Profile at minimum position
Usually with profile against backfence
Étape 3 - Press and hold button until lights flash
Around 3 seconds
Étape 4 - Place profile at maximum position
On an Ecoline, around 60mm
Étape 5 - Press and hold until lights stop flashing
Étape 6 - Test with profile
Ensure it turns off and on in the set window
en
none
0
Draft
Vous avez entré un nom de page invalide, avec un ou plusieurs caractères suivants :
< > @ ~ : * € £ ` + = / \ | [ ] { } ; ? #
Pas encore enregistré ? Créez un compte pour profiter de toutes les fonctionnalités du service !